Which of the following is the most detrimental for water used in high
pressure boiler?
(A) Silica
(B) Turbidity
(C) Phenol
(D) Dissolved oxygen

1 Answer

Answer :

(A) Silica

Related questions

Description : The most detrimental impurity in high pressure boiler feed water is (A) Suspended salt (B) Dissolved salt (C) Silica (D) Turbidity

Last Answer : Option C

Description : Which of the following impurities in feed water for high pressure boiler is the most detrimental? (A) Silica (B) Dissolved oxygen (C) Suspended salt (D) Dissolved salt

Last Answer : (A) Silica

Description : Tri-sodium phosphate is used in boiler water treatment to reduce (A) Turbidity (B) Caustic embrittlement (C) Suspended silica (D) Dissolved oxygen

Last Answer : (B) Caustic embrittlement

Description : Pick out the wrong statement. (A) Caustic embrittlement of boiler's metallic parts is caused by highconcentration of caustic soda in boiler feed water (B) Cooling and freezing of water kills the ... goes on decreasing (D) Dissolved oxygen content in high pressure boiler feed water should be nil

Last Answer : (B) Cooling and freezing of water kills the bacteria present in it

Description : Deaeration of high pressure boiler feed water is done to reduce (A) Foaming from boilers (B) Its dissolved oxygen content (C) Its silica content (D) Caustic embrittlement

Last Answer : (B) Its dissolved oxygen content

Description : The detrimental effect on organism and water quality with temperature rise of aquatic system is the reduction of __________ of water. (A) Dissolved oxygen content (B) Biological oxygen demand (C) Vapor pressure (D) All (A), (B) and (C)

Last Answer : (A) Dissolved oxygen content

Description : Hydrazine is used in water treatment for the removal of (A) Colloidal impurities (B) Dissolved oxygen (C) Turbidity (D) Chlorinous taste

Last Answer : (B) Dissolved oxygen

Description : The best guide to judge the general quality of water is the measurement of its (A) pH value (B) Electrical conductivity (C) Turbidity (D) Dissolved oxygen content

Last Answer : (B) Electrical conductivity

Description : Turbidity of water is an indication of the presence of (A) Suspended inorganic matter (B) Dissolved solids (C) Floating solids (D) Dissolved gases

Last Answer : (A) Suspended inorganic matter

Description : The resistance of water to the passage of light through it is a measure of the (A) Turbidity (B) Color (C) Hardness (D) Dissolved gases

Last Answer : (A) Turbidity

Description : Foaming and priming in boiler operation can be reduced by reduction in __________ in feed water. (A) Turbidity (B) Color (Hazen) (C) Total solids (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Standard unit of turbidity of water is in one litre of distilled water, one milligram of finely divided  (A) Silica  (B) Mud  (C) Clay  (D) Organic matter 

Last Answer : (A) Silica 

Description : Consider the following statements. The following factors relate to the process of coagulation : 1. Percentage removal is higher when turbidity is more 2. Additional of activated silica aids in the process of coagulation 3. pH of water ... 1, 2 and 3 b) 1 and 2 only c) 2 and 3 only d) 1 and 3 only

Last Answer : a) 1, 2 and 3

Description : The temperature of boiling water in a steam engine may be high because - (1) there are dissolved substances in water (2) there is low pressure inside the boiler (3) there is high pressure inside the boiler (4) the lire is at very high temperature

Last Answer : (3) there is high pressure inside the boiler Explanation: In the boiler of a steam engine, there is a firebox where coal is shoveled into. The coal is kept burning at a very high temperature, and ... reservoir; the steam is then controlled by a slide valve to move into a cylinder to push the piston.

Description : The temperature of boiling water in a steam engine may be high because : (1) there are dissolved substances in water (2) there is low pressure inside the boiler (3) there is high pressure inside the boiler (4) the fire is at very high temperature

Last Answer :  there is high pressure inside the boiler

Description : On nephelometry turbidity unit (NTU) is equal to the turbidity produced by (a) 1 mg SiO2 dissolved in 1 l of distilled water with the test being run according to absorption principle (b) 1 ... Formazin dissolved in 1 l o f distilled water with the test being run according to scattering principle.

Last Answer : (d) 1 mg Formazin dissolved in 1 l o f distilled water with the test being run according to scattering principle.

Description : Scale formation in boiler is controlled by (A) Preheating of feed water (B) Reduction in hardness, silica & alumina in feed water (C) Keeping the pH value of feed water just below 7 (D) Eliminating H2S in feed water

Last Answer : (B) Reduction in hardness, silica & alumina in feed water

Description : Soluble silica present in boiler feed water can be removed by (A) Coagulation (B) Filtration (C) Anion exchanger (D) Preheating it

Last Answer : (C) Anion exchanger

Description : Steam condensate is recovered by steam traps and recycled for use as boiler feed water, because of its low (A) Hardness (B) Dissolved solids content (C) Suspended solids content (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : `Br_(2)` dissolved in `CS_(2)` reacts with phenol at 273 K to give ..... as the major product

Last Answer : `Br_(2)` dissolved in `CS_(2)` reacts with phenol at 273 K to give ..... as the major ... . m-Bromophenol C. p-Bromophenol D. 2,4,6-Tribromophenol

Description : Phenolic water generated in coke ovens & by-product plant attached to an integrated steel plant containing phenol in concentration of less than 100 mg/litre can be removed by (A) Chlorination (B) Treating in biological oxygen pond (C) Chemical coagulation (D) None of these

Last Answer : (B) Treating in biological oxygen pond

Description : Detrimental property of a material for shock load applications (a) High density (b) Low toughness (c) High strength (d) Low hardness  

Last Answer : (b) Low toughness

Description : In a rapid sand filter, air binding is caused due to excessive  (A) Negative pressure  (B) Pressure  (C) Turbidity  (D) Water pressure

Last Answer : (A) Negative pressure

Description : Dilution method of disposing of sewage, is not preferred to A. When sewage is fresh B. When diluting water has high dissolved oxygen content C. When diluting water is used for water supply near the point of sewage disposed D. When the diluting water is having flow currents

Last Answer : ANS: C

Description : Pick out the correct statement. (A) Deforestation helps in controlling the green house effect (B) Global warming is detrimental for increase in food productivity and may cause flood and cyclone ( ... natural source of production of SO2 & H2S pollutant (D) Sulphur dioxide causes death by asphyxiation

Last Answer : (B) Global warming is detrimental for increase in food productivity and may cause flood and cyclone

Description : Heavy water used in the nuclear reactors to slow down the speed of neutrons is (A) Highly purified water (B) A compound of oxygen and deuterium (C) Water having dissolved salts of heavy metals (D) None of these

Last Answer : (B) A compound of oxygen and deuterium

Description : Lead pipes are not safe for carrying drinking water because water containing dissolved oxygen attacks lead thereby forming poisonous Pb (OH)2 . Lead pipes are readily corroded by (A) Dilute HCI (B) Acetic acid (C) Concentrated H2SO4 (D) None of these

Last Answer : (B) Acetic acid

Description : Lead pipes are not safe for carrying drinking water, because water, containing dissolved oxygen attacks lead thereby forming poisonous Pb(OH)2 . Lead pipes are readily corroded by (A) Dilute HCl (B) Acetic acid (C) Concentrated H2SO4 (D) None of these

Last Answer : (B) Acetic acid

Description : Dissolved oxygen content in river water is around __________ ppm. (A) 5 (B) 100 (C) 250 (D) 500

Last Answer : (A) 5

Description : . Presence of iron and manganese in water causes (A) Reduction in its dissolved oxygen content (B) Discoloration of bathroom fixtures (C) Temporary hardness (D) None of these

Last Answer : (B) Discoloration of bathroom fixtures

Description : Replenishment of dissolved oxygen in water stream polluted with industrial waste occurs by (A) Natural aeration of water stream (B) Photosynthetic action of algae (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : Lagoons used for purification of polluted water (A) Are large shallow artificial lakes also known as clarification lakes, maturation ponds or oxidation ponds (B) Use micro-organisms/bacteria in presence of dissolved oxygen (C) Gives an ... 1 mg/litre and BOD = 3.8 mg/litre (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : For existence of aquatic life in water, the dissolved oxygen content in it, should not be less than __________ ppm. (A) 10000 (B) 5 (C) 500 (D) 1000

Last Answer : (B) 5

Description : Presence of non-biodegradable substances, like alkyl benzene sulphonate (ABS) from the detergents in polluted water stream causes (A) Fire hazards (B) Explosion hazards (C) Persistent foam (D) Depletion of dissolved oxygen

Last Answer : (C) Persistent foam

Description : Use of water having dissolved oxygen in boilers promotes (A) Corrosion (B) Sequestration (C) Scale formation (D) None of these

Last Answer : (A) Corrosion

Description : The domestic sewage in large cities (a) has a high BOD as it contains both aerobic and anaerobic bacteria (b) is processed by aerobic and then anaerobic bacteria in the secondary treatment in ... sewage contains adequate oxygen (d) has very high amount of suspended solids and dissolved salts.

Last Answer : (b) is processed by aerobic and then anaerobic bacteria in the secondary treatment in Sewage Treatment Plants (STPs)

Description : Presence of carbonaceous matter in the sewage (A) Causes reduction in its dissolved oxygen content thereby endangering the life of aquatic creatures (B) Reduces sulphate ions to sulphides causing obnoxious ... quantity of chlorine used for its purification (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Heat transfer to the water wall in a high pressure water wall type boiler furnace is mainly by (A) Conduction (B) Convection (C) Radiation (D) Both 'a' & 'b'

Last Answer : Option C

Description : Presence of bacteria in potable (drinking) water causes (A) Turbidity (B) Disease (C) Bad odour (D) Bad taste & colour

Last Answer : (B) Disease

Description : Maximum permissible turbidity in potable water is __________ ppm. (A) 1 (B) 10 (C) 250 (D) 1000

Last Answer : (B) 10

Description : Presence of nitrogen and phosphorous in waste water discharged into lakes and ponds causes (A) Foaming (B) Odour nuisances (C) Undesirable plant growth (D) Turbidity

Last Answer : (C) Undesirable plant growth

Description : Removal of __________ results from the disinfection of water. (A) Turbidity (B) Odour (C) Hardness (D) Bacteria

Last Answer : (D) Bacteria

Description : Deaeration of water in its treatment is necessary, as it (A) Minimises its turbidity (B) Helps in controlling its taste and odour (C) Minimises its corrosiveness (D) None of these

Last Answer : (C) Minimises its corrosiveness

Description : Alum [Al2 (SO4 )3 ] is used as a coagulant in water treatment to remove (A) Colour (B) Turbidity (C) Bacteria (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Pick out the true statement pertaining to water treatment. (A) Slow sand filters can remove colour completely (B) Activated carbon can be used for taste & odour control without subsequent filtration ... of water (D) Normally, the turbidity is removed by adding a coagulant prior to sedimentation

Last Answer : (D) Normally, the turbidity is removed by adding a coagulant prior to sedimentation

Description : The main use of activated carbon in water treatment is to control (A) Bacterial growth (B) Taste and odour (C) Turbidity (D) None of these

Last Answer : (B) Taste and odour

Description : Chloramines are used in water treatment for (A) Disinfection and control of taste & odour (B) Corrosion control (C) Removing turbidity (D) Control of bacteria

Last Answer : (A) Disinfection and control of taste & odour

Description : . Dechlorination of treated water is necessary to (A) Remove residual turbidity (B) Reduce the bacterial load on filter (C) Control taste and odour (D) Remove chlorinous taste

Last Answer : (D) Remove chlorinous taste

Description : Radiation heat losses from satisfactorily insulated high pressure boiler may be about __________ percent. (A) 1 (B) 7 (C) 18

Last Answer : (B) 7

Description : Which one is not an induced draught furnace? (A) Blast furnace stove (B) Sintering furnace (C) High pressure boiler (D) None of these