The value of COP in vapour compression cycle is usually (a) always less than unity (b) always more than unity (c) equal to unity (d) any one of the above

1 Answer

Answer :

Ans: b

Related questions

Description : The COP of a vapour compression plant in comparison to vapour absorption plant is (a) more (b) less (c) same (d) more/less depending on size of plant

Last Answer : Ans: a

Description : Most of the domestic refrigerators work on the following refrigeration system (a) vapour compression (b) vapour absorption (c) carnot cycle (d) electrolux refrigerator

Last Answer : Ans: a

Description : In vapour compression cycle using NH3 as refrigerant, initial charge is filled at (a) suction of compressor (b) delivery of compressor (c) high pressure side close to receiver (d) low pressure side near receiver

Last Answer : Ans: c

Description : The lower horizontal line of the refrigeration cycle plotted on pressure-enthalpy-diagram represents (a) condensation of the refrigerant vapour (b) evaporation of the refrigerant liquid (c) compression of the refrigerant vapour (d) metering of the refrigerant liquid

Last Answer : Ans: b

Description : Where does the lowest temperature occur in a vapour compression cycle ? (a) condenser (b) evaporator (c) compressor (d) expansion valve

Last Answer : Ans: b

Description : The higher temperature in vapour compression cycle occurs at (a) compressor discharge. (b) expansion valve (c) evaporator (d) condenser discharge

Last Answer : Ans: a

Description : In a vapour compression cycle, the refrigerant immediately after expansion valve is (a) liquid (b) sub-cooled liquid (c) saturated liquid (d) wet vapour

Last Answer : Ans: d

Description : Domestic refrigerator working on vapour compression cycle uses the following type of expansion device (a) electrically operated throttling valve (b) manually operated valve (c) thermostatic valve (d) capillary tube

Last Answer : Ans: d

Description : The vapour compression refrigerator employs the following cycle (a) Rankine (b) Carnot (c) Reversed Carnot. (d) Brayton

Last Answer : Ans: c

Description : In vapour compression cycle the condition off refrigerant is dry saturated vapour (a) after passing through the condenser (b) before passing through the condenser (c)before entering the expansion valve (d) before entering the compressor

Last Answer : Ans: D

Description : In vapour compression cycle the condition of refrigerant is superheated vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) beforeentering the expansion valve

Last Answer : Ans: b

Description : In vapour compression cycle, the condition of refrigerant is high pressure saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve

Last Answer : Ans: d

Description : In vapour compression cycle, the condition of refrigerant is very wet vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve

Last Answer : Ans: c

Description : In vapour compression cycle, the condition of refrigerant is saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion throttle valve (d) before entering the expansion valve

Last Answer : Ans: a

Description : Ammonia-absorption refrigeration cycle requires (a) very little work input (b) maximum work input (c) nearly same work input as for vapour compression cycle (d) zero work input

Last Answer : Ans: a

Description : Vapour compression refrigeration is some what like (a) Carnot cycle (b) Rankine cycle (c) reversedCamot cycle (d) reversed Rankine cycle

Last Answer : Ans: C

Description : Which of the following has the minimum value of COP for a given refrigeration effect? (A) Reverse Carnot cycle (B) Ordinary vapour-compression cycle (C) Vapour-compression process with a reversible expansion engine (D) Air refrigeration cycle

Last Answer : (D) Air refrigeration cycle

Description : The effect of changing the evaporator temperature on COP as compared to that of changing the condenser temperature (in vapour compression refrigeration system) is (A) Less pronounced (B) More pronounced (C) Equal (D) Data insufficient, can't be predicted

Last Answer : (B) More pronounced

Description : Efficiency of a Carnot engine is given as 80%. If the- cycle direction be reversed, what will be the value of COP ofreversed Carnot cycle (a) 1.25 (b) 0.8 (c) 0.5 (d) 0.25

Last Answer : Ans: d

Description : The COP of a domestic refrigerator (a) is less than 1 (b) is more than 1 (c) is equal to 1 (d)depends upon the weather conditions.

Last Answer : Ans: b

Description : A diesel engine is usually more efficient than a spark ignition engine because a. Diesel being a heavier hydrocarbon, release more heat per kg than gasoline b. The air standard efficiency of diesel ... an Spark ignition engine d.Self ignition temperature of diesel is higher than that of gasoline.

Last Answer : ANSWER c. The compression ratio of a diesel engine is higher than that of an S.I engine

Description : What is the use of flash chamber in a vapour compression refrigeration cycle to improve the COP of refrigeration cycle ?

Last Answer : When liquid refrigerant as obtained from condenser is throttled, there are some vapours. These vapours if carried through the evaporator will not contribute to refrigerating effect. Using a flash ... out in stages. Similarly compression process is also done in two separate compressor stages.

Description : Out of the following refrigeration cycles, which one has the minimum COP (Co-efficient of performance)? (A) Air cycle (B) Carnot cycle (C) Ordinary vapour compression cycle (D) Vapour compression with a reversible expansion engine

Last Answer : A) Air cycle

Description : Under-cooling in a refrigeration cycle (a) increases COP (b) decreases COF (c) COP remains unaltered (d) other factors decide COP

Last Answer : Ans: a

Description : Superheating in a refrigeration cycle (a) increases COP (b) decreases COP (c) COP remains unaltered (d) other factors decide COP

Last Answer : Ans: b

Description : If a heat pump cycle operates between the condenser temperature of +27°C and evaporator temperature of - 23°C,then the Carnot COP will be (a) 0.2 (b) 1.2 (c) 5 (d) 6

Last Answer : Ans: d

Description : For same compression ratio a. Diesel cycle has lower efficiency than Otto cycle b. Diesel cycle has higher efficiency than Otto cycle c. Diesel cycle and Otto cycle have equal efficiencies d. Depends upon the load on engine

Last Answer : Answer a. Diesel cycle has lower efficiency than Otto cycle

Description : The condition of refrigerant before entering the expansion or throttle valve, in a vapour compression system (a) dry vapour (b) wet vapour (c)liquid-vapour mixture (d) high pressure saturated liquid

Last Answer : Ans: d

Description : In vapour compression refrigeration system, refrigerant occurs as liquid between (a) condenser and expansion valve (b) compressor and evaporator (c) expansion valve and evaporator (d) compressor and condenser

Last Answer : Ans: c

Description : For better COP of refrigerator, the pressure range corresponding to temperature in evaporator and condenser must be (a) small (b) high (c) equal (d) anything

Last Answer : Ans: a

Description : For obtaining high COP, the pressure range of compressor should be (a) high (b) low (c) optimum (d) any value

Last Answer : Ans: b

Description : Pick up the incorrect statement (a) lithium bromide used in vapour absorption cycle is nonvolatile (b) lithium bromide plant can't operate below 0°C (c) a separator is used in lithium ... of solution coming out of lithium bromide generator is more in comparison to that entering the generator

Last Answer : Ans: c

Description : Reducing suction pressure in refrigeration cycle (a) lowers evaporation temperature (b) increases power required per ton of refrigeration (c) lowers compressor capacity because vapour is lighter (d) all of the above.

Last Answer : Ans: d

Description : For same compression ratio and heat input a. Otto cycle is more efficient b. Diesel cycle is more efficient c. Both are equally efficient d. None of the above

Last Answer : ANSWER a. Otto cycle is more efficient

Description : Lowering of condenser temperature (keeping the evaporator temperature constant) in case of vapour compression refrigeration system results in (A) Increased COP (B) Same COP (C) Decreased COP (D) Increased or decreased COP; depending upon the type of refrigerant

Last Answer : (A) Increased COP

Description : In vapour compression refrigeration system, if the evaporator temperature and the condenser temperatures are -13°C and 37°C respectively, the Carnot COP will be (A) 5.2 (B) 6.2 (C) 0.168 (D) Data insufficient, can't be found out

Last Answer : A) 5.2

Description : Most high speed compression ignition engine operate on A. dual cycle B. otto cycle C. diesel cycle D.Carnot cycle

Last Answer : ANSWER : A

Description : The ratio of work done per cycle to the stroke volume of the compressor is known as A. Compressor capacity B. Compression ratio C. Compressor efficiency D. Mean effective pressure

Last Answer : ANSWER : D

Description : Most high-speed compression engines operate on a. diesel cycle b. Otto cycle c. dual cycle d. Carnot cycle

Last Answer : ANSWER c. dual cycle

Description : The thermal efficiency of a diesel cycle having fixed compression ratio with increase in cut-off ratio will a. increase b. decrease c. independent d. increase or decrease depending upon other factors

Last Answer : ANSWER b. decrease

Description : An ideal air standard Otto cycle has a compression ratio of 8.5. If the ratio of the specific heats is 1.4, then what is thermal efficiency (in percentage) of the Otto cycle? a. 57.5% b. 45.7% c. 52.5% d. 95%

Last Answer : ANSWER a. 57.5%

Description : If the compression ratio of an engine working on Otto cycle is increased from 5 to 7 the percentage increase in efficiency will be a. 2% b. 4% c. 8% d. 14%

Last Answer : ANSWER d. 14%

Description : What is the relation between compression ratio (rk) and the efficiency of the Otto cycle? a. efficiency decreases with increase in compression ratio b. efficiency increases with increase in compression ratio c. efficiency is not affected by change in compression ratio d. none of the above

Last Answer : ANSWER b. efficiency increases with increase in compression ratio

Description : What is the formula for compression (rk) ratio of the Otto cycle? a. rk = Volume of cylinder at the beginning of compression / Volume of cylinder at the end of compression b. rk = Volume of cylinder ... c. rk = Volume of cylinder at the end of compression / clearance volume d. none of the above

Last Answer : ANSWER a. rk = Volume of cylinder at the beginning of compression / Volume of cylinder at the end of compression

Description : The efficiency of the Otto cycle is independent of a. Heat supplied b. Compression ratio c. Ratio of specific heats d. None of the above

Last Answer : Answer a. Heat supplied

Description : Which of the following cycle is used for Compression Ignition engine? a. Otto cycle b. Diesel cycle c. Dual cycle d. Carnot cycle

Last Answer : Answer b. Diesel cycle

Description : The vapour pressure of refrigerant should be (a) lower than atmospheric pressure (b) higher than atmospheric pressure (c) equal to atmospheric pressure (d) could be anything

Last Answer : Ans: b

Description : The relative coefficient of performance is (a) actual COP/theoretical COP (b) theoretical COP/actual COP (c) actual COP x theoretical COP (d) 1-actual COP x theoretical COP

Last Answer : Ans: a

Description : Relative humidity is a) the ratio of water vapour in the air compared to the total amount water vapour the air could contain at a given temperature b) equal to the dry bulb temperature divided by the wet bulb ... of dry air e) the ratio of the mass of water vapour divided by the mass of wet air

Last Answer : ANSWER : A

Description : The change in evaporator temperature in a refrigeration cycle, as compared to change in condenser temperature, influences the value of C.O.P. (a) more (b) less (c) equally. (d) unpredictable

Last Answer : Ans: a