Primary winding of a transformer could either be a low voltage or high voltage winding.

Like 0 like

Please log in or register to answer this question.

Related questions

286 views

Description : In a transformer the resistance between its primary and secondary should be?

Last Answer : In a transformer the resistance between its primary and secondary should be infinity.

1 answer
203 views

Last Answer :  Sandwich type winding is used in 3 phase shell-type transformer.

1 answer
233 views

Description : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Last Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

1 answer
176 views

Last Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

1 answer
174 views

Last Answer : yes High Voltage side of Transformer winding have more number of turns. and low voltage side of Transformer winding have less number of turns.

1 answer
264 views

Last Answer : In the transformer low voltage winding has got more cross-sectional area.

1 answer
379 views

Last Answer : High voltage winding in a transformer has more number of turns.

1 answer
112 views

Last Answer : High voltage winding of the transformer has less cross-sectional area.

1 answer
192 views

Description : Define: primary and secondary distribution system 

Last Answer : i) Primary Distribution:  It is a 3-phase, 3-wire transmission line connected in between receiving substation to Distribution substation. OR It is link between receiving substation & ... substation to consumer line. OR It is link between distribution transformer substation & consumer. 

1 answer
189 views

Description : Write example of each type (i) Primary transducer (ii) Active transducer (iii) Electrical transducer (iv) Digital transducer

Last Answer : (i) Active transducer:-Thermocouple, piezoelectric, photovoltaic cell (ii) Primary transducer:- Bourdon tube, bellows, (iii) Electrical transducer.:- LVDT,RVDT, Hall effect, strain gauge, ... , optical pyrometer, radiation pyrometer (iv) Digital transducer:- Linear Encoder, digital taco generator

2 answers
94 views

Description : Compare primary and secondary instruments.

Last Answer : Primary instruments  Secondary instruments  Gives magnitude of quantity in terms of physical constants of instrument  Gives reading directly of the quantity measured.  Need no calibration  ... .  e.g. magnetic meter, induction meter, hotwire meter and electrostatic meter 

1 answer
121 views

Last Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

1 answer
82 views

Description : What is the definition of a primary instrument?

0 answers
410 views

Description : Primary and Backup Protection

Last Answer : Primary and Backup Protection  B,D,G,I are the primary protection. A,C,H,J are the backup protection. About 90% of faults are clear by Primary Protection. So ... ordinated backup (primary is at various station  and backup is at control room with computer)

1 answer
500 views

Description : State advantages of short pitch winding over full pitch winding in alternators. 

Last Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

1 answer
107 views

Last Answer : It is the wire wound around a aluminium metal it is found commonly in transformers or motors

1 answer
92 views

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.

1 answer
3.4k views

Description : A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

1 answer
357 views

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

1 answer
603 views

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

1 answer
101 views

Description : Damper winding is provided in 3 phase synchronous motors to :

Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

1 answer
625 views

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

1 answer
92 views

Last Answer : Wave winding is composed of that even number which is exact multiple of poles + 2.

1 answer
130 views

Last Answer : Lap winding is composed of any even number of conductors.

1 answer
96 views

Last Answer : In D.C. generators, lap winding is used for low voltage, high current.

1 answer
123 views

Last Answer : In the case of lap winding resultant pitch is difference of front and back pitches.

1 answer
670 views

Last Answer : In case of D.C. machine winding, number of commutator segments is equal to number of armature coils.

1 answer
327 views

Last Answer : In lap winding, the number of brushes is always same as the number of poles.

1 answer
218 views

Last Answer : The resistance of armature winding depends on length of conductor, cross-sectional area of the conductor, number of conductors.

1 answer
358 views

Last Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

1 answer
126 views

Last Answer : The starting winding of a single-phase motor is placed in stator.

1 answer
240 views

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

1 answer
217 views

Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

1 answer
229 views

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

1 answer
114 views

Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

1 answer
87 views

Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

1 answer
147 views

Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

1 answer
78 views

Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

1 answer
117 views

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

1 answer
891 views

Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

1 answer
215 views

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

1 answer
725 views

Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

1 answer
105 views

Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

1 answer
264 views

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

1 answer
162 views

Description : The damping winding in synchronous motor is generally used to?

Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

1 answer
517 views

Description : In synchronous motor, does the winding losses vary with load?

Last Answer : No, in the synchronous motor the winding losses do not vary with load.

1 answer
348 views

Last Answer : An ideal transformer has infinite values of primary and secondary inductances. The statement is false.

1 answer
370 views

Description : 28.In a two winding transformer, the emf /turn in secondary winding is always......the induced emf power turn in primary A. equal to k times B. equal to 1/k times C. equal D. greater than

Last Answer : C. equal

1 answer
464 views

Description : 6 In a two winding transformer, the primary and secondary induced emf E1 & E2 are always A. equal in magnitude B. anti phase with each other C. in phase with each other D. determined by load on transformer secondary

Last Answer : C. In phase with each other

1 answer
45 views

Description : 12] Which is not the basic element of the transformer? A. core B. primary winding C. secondary winding D. mutual flux

Last Answer : D. Mutual flux