1 Answer

Answer :

In lap winding, the number of brushes is always same as the number of poles.

Related questions

Last Answer : Lap winding is composed of any even number of conductors.

Last Answer : In D.C. generators, lap winding is used for low voltage, high current.

Last Answer : In the case of lap winding resultant pitch is difference of front and back pitches.

Last Answer : The number of brushes in a commutator depends on amount of current to be collected.

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Last Answer : The rapid wear of brushes takes place due to abrasion from dust, excessive spring pressure, rough commutator bars, high mica insulation between com-mutation bars.

Last Answer : Armature coil is short circuited by brushes when it lies along neutral axis.

Last Answer : The material for commutator brushes is generally carbon.

Last Answer : Brushes of D.C. machines are made of carbon.

Last Answer : Copper brushes in D.C. machine are used where low voltage and high currents are involved.

Last Answer : In case of D.C. machine winding, number of commutator segments is equal to number of armature coils.

Last Answer : Wave winding is composed of that even number which is exact multiple of poles + 2.

Last Answer : The resistance of armature winding depends on length of conductor, cross-sectional area of the conductor, number of conductors.

Description : In a DC motor, it is important to place the brushes along ______ A) Magnetic Neutral Axis B) Normal Geometric Axis C) Nominal Geometric Axis D) None of these

Last Answer : In a DC motor, it is important to place the brushes along Magnetic Neutral Axis

Description : Brushes of DC machine are made up of ?

Last Answer : Brushes of DC machine are made up of carbon.

Last Answer : yes High Voltage side of Transformer winding have more number of turns. and low voltage side of Transformer winding have less number of turns.

Description : State advantages of short pitch winding over full pitch winding in alternators. 

Last Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

Last Answer : It is the wire wound around a aluminium metal it is found commonly in transformers or motors

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Description : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Last Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Description : A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : Damper winding is provided in 3 phase synchronous motors to :

Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

Last Answer : The starting winding of a single-phase motor is placed in stator.

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Last Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Last Answer : Primary winding of a transformer could either be a low voltage or high voltage winding.

Last Answer :  Sandwich type winding is used in 3 phase shell-type transformer.

Description : The damping winding in synchronous motor is generally used to?

Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

Description : In synchronous motor, does the winding losses vary with load?

Last Answer : No, in the synchronous motor the winding losses do not vary with load.

Description : In lap winding, the number of brushes is always (a) double the number of poles (b) same as the number of poles (c) half the number of poles (d) two

Last Answer : Ans: b

Description : What number is your Willpower?

Last Answer : 10 but then I cheated so I don’t know… but I’m being honest about it so 10 or am I lying again… so definitely between 1 and 10

Description : What is the choice of size and number of generator units in interconnected power system?

Last Answer : Choice of Size and Number of Generating Units: 1. The size/rating and number of generating units in such way that they approximately match with the load curve as closely as possible. 2. In ... , if power plant is connected to grid system then generating unit of higher capacity can be installed.

Description :  The number of loop equations required to completely analysing a network comprising of 8 independent branches and 6 nodes including the reference node shall be A) 3 B) 2 C) 4 D) 5 

Last Answer :  The number of loop equations required to completely analysing a network comprising of 8 independent branches and 6 nodes including the reference node shall be 3 

Description :  A connected graph has ‘5’ number of branches and ‘4’ number of nodes. It's rank is A) 1 B) 2 C) 3 D) 4 

Last Answer :  A connected graph has ‘5’ number of branches and ‘4’ number of nodes. It's rank is 3 

Description : Then number of T-states of the instruction STA in 8085 microprocessor is A) 10 B) 12 C) 13 D) 16 

Last Answer : Then number of T-states of the instruction STA in 8085 microprocessor is 13