Can I burn old motor oil in my oil burning furnace?

1 Answer

Answer :

No you cannot. Old motor oil contains harmful additives that can be released back into the atmosphere and can make you sick. Don't do it.

Related questions

Description : A _______ incorporates a firebox or furnace in order to burn the fuel and generate heat. • Steam • Boiler • Hydrogen • None

Last Answer : • Boiler

Description : A -________ incorporates a firebox or furnace in order to burn the fuel and _________ heat. a. Boiler, generate b. Heat, boiler c. Steam, pressure d. None

Last Answer : a. Boiler, generate

Description : A _______ incorporates a firebox or furnace in order to burn the fuel and generate heat. A Steam B Boiler C Hydrogen D None

Last Answer : B Boiler

Description : Is the mass of wood and oxygen that allow it to burn equal the mass of ashes and the gas given off during the burning?

Last Answer : Yes. According to the law of conservation of mass, the mass ofall the reactants must be equal to the mass of all of theproducts.

Description : What is the function of boiler? • To burn the fuel in a confined closed system With the supply of air • To generate steam in varying pressure • To generate steam at constant pressure • To produce flue gases by burning fuel at a given pressure

Last Answer : • To generate steam at constant pressure

Description : Cost of a wood burning furnace?

Last Answer : A wood burning furnace installed will run you a few thousand dollars and as much as four or five thousand dollars. That being said your heat bill will be cut down to almost nothing and you can probably get a rebate on your taxes for getting a energy efficient appliance.

Description : Overfire burning in a furnace is a phenomenon characterised by (A) Supply of excess fuel (B) Supply of excess air (C) Burning carbon monoxide and other incombustible in upper zone of furnace by supplying more air (D) None of these

Last Answer : (C) Burning carbon monoxide and other incombustible in upper zone of furnace by supplying more air

Description : The advantages of firing pulverised coal in the furnace lies in the fact that, it (A) Permits the use of high ash content coal (B) Permits the use of low fusion point ash coal (C) Accelerates the burning rate and economises on fuel consumption (D) All (A), (B) and (C)

Last Answer : (C) Accelerates the burning rate and economises on fuel consumption

Description : Which of the following accentuates clinkering troubles on furnace grate burning coal? (A) Low reactivity of carbonised residue containing high proportion of iron & sulphur (B) Low forced draft & fuel bed temperature (C) Thick firebed and preheated primary air (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Use of pulverised coal in boilers provides (A) Higher calorific value (B) Better combustion (C) Smokeless burning (D) Less erosion on furnace wall

Last Answer : (B) Better combustion

Description : Which of the following accentuates clinkering trouble on furnace grate burning coal? (A) Low reactivity of carbonised residue containing high proportions of iron & sulphur (B) Low forced draught and fuel bed temperature (C) Thick fire bed and preheated primary air (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Use of pulverised coal in boiler furnace provides (A) High calorific value (B) Better combustion (C) Smokeless burning (D) Less erosion on furnace walls

Last Answer : (B) Better combustion

Description : The advantage of firing pulverised coal in the furnace lies in the fact, that it (A) Permits the use of high ash content coal (B) Permits the use of low fusion point ash coal (C) Accelerates the burning rate and economises on fuel combustion (D) All (A), (B) and (C)

Last Answer : (C) Accelerates the burning rate and economises on fuel combustion

Description : Overfire burning" in a furnace is a phenomenon characterised by the (A) Supply of excess fuel (B) Supply of excess air (C) Burning of carbon monoxide and other incombustibles in upper zone of furnace by supplying more air (D) None of these

Last Answer : (C) Burning of carbon monoxide and other incombustibles in upper zone of furnace by supplying more air

Description : 'Flare tower' used in industry is meant for (A) Venting off (after burning) the excess inflammable/toxic gases at high pressure (B) Absorbing the pollutant gases from the furnace exhaust (C) Cooling of furnace exhaust gases (D) None of these

Last Answer : (A) Venting off (after burning) the excess inflammable/toxic gases at high pressure

Description : Got a DVD stuck in my Macbook, will the motor burn and start a fire?

Last Answer : You’re fine. And there are lots of ways to get it out.

Description : If the residual flux is absent in the rotor iron of the isolated induction generator, a) it will not run. b) it will run as induction motor c) it will burn the winding d) it will not affect the characteristic of the generator

Last Answer : Ans: A

Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed

Last Answer : Answer: B

Description : Which of the following problems will most likely occur if the starting winding of a split-phase induction motor failed to cutout once the motor was in continuous operation? A. The motor will overspeed. B. The ... reduced speed. C. A time delay will stop the motor. D. The winding will burn out.

Last Answer : Answer: D

Description : Which of the following conditions will occur if the solenoid coil burns out on a cargo winch with an electrical brake? A. The brake will be set by spring force. B. The motor will overspeed and burn ... the cargo boom will fall. D. Nothing will happen; the winch will continue to operate as usual.

Last Answer : Answer: A

Description : In centrifugal pump installation,  (A) Pump is properly primed before starting  (B) The diameter of the pipe at inlet as well as at outlet, is kept smaller than the delivery pipe  (C) The ... out if it is started with empty delivery pipe and with open gate valve  (D) All the above 

Last Answer : (D) All the above 

Description : 58 If a pump motor is run on 2/3rd of its supply voltage, it will A. Continue to deliver same power B. burn C. stall D. continue to run at lower speed

Last Answer : C. Stall

Description : Pick out the wrong statement. (A) LPG is also used as fuel for automobiles & small furnaces and for cutting & welding of metals (B) The minimum temperature, at which a petroleum oil vapor catches ... about 30-50 Nm3 of gas (D) Maximum yield of naphthalene is obtained on distillation of crude oil

Last Answer : (B) The minimum temperature, at which a petroleum oil vapor catches fire and continues to burn, is called its flash point

Description : Preheating before welding is done to (A) Make the plate softer (B) Burn oil & grease sticking to plate surfaces (C) Avoid plate distortion (D) Prevent cold cracks

Last Answer : (D) Prevent cold cracks

Description : Furnace in house won't start up after the oil has been refueled. Advice please?

Last Answer : Did the oil tank run dry? If so, you probably have air in the line and need to bleed it. It’s a pain and can be very messy.

Description : How to Clean an Oil Furnace Heat Exchanger?

Last Answer : If you have a heat exchanger within your oil furnace, you probably know that it is of vital importance that you must regularly clean out the buildup of soot inside of it. You should probably do ... the manual which came with your oil furnace, a small brush that has stiff feeling bristles, a flashli

Description : rate the efficiency and quality of oil fired furnace manufacturers.?

Last Answer : I would look it up in consumer reports if you have it or if not go to the library. Also online people rate stuff all the time and they can tell you what the good ones are and what to ... an article on that subject, and pretty soon you'll know what the most efficient quality oil fired furnace is.

Description : Can I buy furnace oil at Home Depot?

Last Answer : Home Depot carries a lot of things and may very well carry the oil you need for your furnace. They also carry kerosene and other fuels for heating.

Description : Where can I buy a new oil furnace?

Last Answer : Your local heating and air company can very well assist you with your new furnace purchase. Check your telephone directory and call them for quotes to see if they are within your budget.

Description : LSHS is a type of furnace oil, which (A) Is more viscous than high viscosity furnace oil (HVFO) (B) Stands for low sulphur heavy stock (C) Is an ideal fuel for metallurgical furnaces due to its lower sulphur content (< 1%) (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Which of the following has the maximum °API gravity of all? (A) Diesel (B) Kerosene (C) Petrol (D) Furnace oil

Last Answer : (C) Petrol

Description : Maximum sulphur percentage in low sulphur heavy stock (LSHS) furnace oil is about (A) 0.1 (B) 1 (C) 2.5 (D) 3.5

Last Answer : (B) 1

Description : Preheating temperature of medium viscosity furnace oil for better atomisation through burner is about __________ °C. (A) 50 (B) 70 (C) 90 (D) 140

Last Answer : (C) 90

Description : Which of the following petroleum products contain minimum sulphur? (A) Naphtha (B) Kerosene (C) LSHS (D) Furnace oil

Last Answer : (A) Naphtha

Description : Which of the following does not require preheating during storage in the storage tank as well as during atomisation through burners? (A) PCM (B) Tar (C) Light diesel oil (D) Low viscosity furnace oil

Last Answer : (C) Light diesel oil

Description : Which of the following has the minimum °API gravity of all? (A) Diesel (B) Kerosene (C) Petrol (D) Furnace oil

Last Answer : (D) Furnace oil

Description : Which of the following is not an important property of fuel oil/furnace oil? (A) Sulphur content (B) Viscosity (C) Aniline point (D) Flash point

Last Answer : (C) Aniline point

Description : The function of an economiser in a boiler is to preheat the (A) Feedwater (B) Combustion air (C) Pulverised coal (D) Furnace oil

Last Answer : (A) Feedwater

Description : Out of the following fuels used in a furnace exhausting flue gas at a temperature of 600°C, the percentage stack loss will be maximum in case ofcomplete combustion of (A) Furnace oil with air (B) Furnace oil with oxygen (C) Blast furnace gas with air (D) Blast furnace gas with oxygen

Last Answer : (C) Blast furnace gas with air

Description : Combustion of furnace oil in a furnace (soaking pit) with preheated combustion air at 400°C results in saving of about __________ percentfurnace oil as compared to its combustion with atmospheric air, if the flue gas outlet temperature from the soaking pit is 1200°C. (A) 5 (B) 60 (C) 20 (D) 40

Last Answer : (C) 20

Description : Fuel used in B.F. stove is (A) Pulverised coal (B) Furnace oil (C) Blast furnace gas/mixed gas (D) Coke oven gas

Last Answer : (C) Blast furnace gas/mixed gas

Description : Calorific value of furnace oil is about __________ Kcal/kg. (A) 10,000 (B) 15,000 (C) 5,000 (D) 20,000

Last Answer : (A) 10,000

Description : Which of the following fuels is generally not used in thermal power plant boiler firing? (A) Furnace oil, light diesel oil and tar/PCM (B) Pulverised coking coal (C) Coal middling from washeries (D) B.F. gas, coke oven gas and L.D. converter gas

Last Answer : (B) Pulverised coking coal

Description : Which of the following is not a manufactured fuel? (A) Furnace oil (B) Bagasse (C) Semi-coke (D) Kerosene

Last Answer : (B) Bagasse

Description : Which of the following fuels has the highest calorific value per unit mass (kcal/kg)? (A) Coal (B) Kerosene (C) Natural gas (D) Furnace oil

Last Answer : (D) Furnace oil

Description : Which of the following would require maximum amount of % excess air for complete combustion? (A) Coke oven gas (B) Furnace oil (C) Pulverised coal (D) Lump coal (fixed on chain grate)

Last Answer : (D) Lump coal (fixed on chain grate)

Description : . C/H ratio is the minimum in case of (A) Furnace oil (B) Natural gas (C) Coal (D) Naphtha

Last Answer : (B) Natural gas

Description : Which of the following has the highest gross calorific value? (A) Blast furnace gas (B) Coke oven gas (C) Carburetted water gas (D) Oil refinery gas

Last Answer : (D) Oil refinery gas

Description : Tar is a better fuel than furnace oil, because of its (A) Higher calorific value (B) Lower sulphur content (C) Higher emissivity (0.8-0.9) resulting in higher radiation heat transfer rate (D) Both (A) and (B)

Last Answer : (D) Both (A) and (B)

Description : Correct viscosity of furnace oil at the burner tip for proper atomisation is about 25 centistokes. To reduce the viscosity of high viscosity furnace oil (250 centistokes) to the correct atomisation viscosity (i.e. 25 cst), it should be preheated to about ___________°C. (A) 70 (B) 85 (C) 105 (D) 145

Last Answer : (C) 105