What degrees of superheat does a refrigerant system evaporator run?

1 Answer

Answer :

Feel Free to Answer

Related questions

Description : In a flooded evaporator refrigerator, an accumulator at suction of compressor is used to (a) collect liquid refrigerant and prevent it from going to compressor (b) detect liquid in vapour (c) superheat the vapour (d) increase refrigeration effect

Last Answer : Ans: a

Description : Choose the correct statement (a) A refrigerant should have low latent heat (b) If operating temperature of system is low, then refrigerant with low boiling point should be used (c) Pre-cooling and sub-cooling bf refrigerant are same (d) Superheat and sensible heat of a. refrigerant are same

Last Answer : Ans: b

Description : What does a low evaporator superheat indicate?

Last Answer : Feel Free to Answer

Description : In vapour compression refrigeration system, refrigerant occurs as liquid between (a) condenser and expansion valve (b) compressor and evaporator (c) expansion valve and evaporator (d) compressor and condenser

Last Answer : Ans: c

Description : Lowering of condenser temperature (keeping the evaporator temperature constant) in case of vapour compression refrigeration system results in (A) Increased COP (B) Same COP (C) Decreased COP (D) Increased or decreased COP; depending upon the type of refrigerant

Last Answer : (A) Increased COP

Description : ____________is the difference between the saturation temperature for the given pressure and the actual sub cooled liquid temperature.  a) Degrees of Superheat, °SH  b) Degrees of Sub cooled, °SB  c) Both a and b  d) None of the above

Last Answer : Degrees of Sub cooled, °SB

Description : _____________ is the difference between the actual temperature of superheated vapor and the saturation temperature for the existing pressure.  a) Degrees of Superheat, °SH  b) Degrees of Sub cooled, °SB  c) Both a and b  d) None of the above

Last Answer : Degrees of Superheat, °SH

Description : Steam is throttled to 0.1 MPa with 20 degrees of superheat. (a) What is the quality of throttled steam if its pressure is 0.75 MPa (b) What is the enthalpy of the process?  a) 97.6%,2713 kJ/kg  b) -97.6%, 2713 kJ/kg  c) 87.6%,3713 kJ/kg  d) -87.6%, 3713 kJ/kg

Last Answer : 97.6%,2713 kJ/kg

Description : The C.O.P. of a refrigeration cycle with lowering of condenser temperature, keeping the evaporator temperatureconstant, will (a) increase (b) decrease (c) may increase or decrease depending on the type of refrigerant used (d) remain unaffected

Last Answer : Ans: a

Description : The C.O.P of a refrigeration cycle with increase in evaporator temperature, keeping condenser temperature constant, will (a) increase (b) decrease (c) remain unaffected (d) may increase or decrease depending on the type of refrigerant used

Last Answer : Ans: a

Description : Choose the wrong statement (a) Temperature of medium being cooled must be below that of the evaporator (b) Refrigerant leaves the condenser as liquid (c) All solar thermally operated absorption systems are capable only of intermittent operation (d) frost on evaporator reduces heat transfer

Last Answer : Ans: a

Description : In a refrigeration cycle, the flow of refrigerant is controlled by (a) compressor (b) condenser (c) evaporator (d) expansion valve

Last Answer : Ans: d

Description : Condensing temperature in a refrigerator is the temperature (a) of cooling medium (b) of freezing zone (c) of evaporator (d) at which refrigerant gas becomes liquid

Last Answer : Ans: d

Description : The bank of tubes at the back of domestic refrigerator are (a) condenser tubes (b) evaporator tubes (c) refrigerant cooling tubes (d) capillary tubes

Last Answer : Ans: a

Description : The moisture in a refrigerant is removed by (a) evaporator (b) safety relief valve (c) dehumidifier (d) driers

Last Answer : Ans: d

Description : The bank of tubes located at the back of the domestic refrigerators are the __________ tubes. (A) Refrigerant cooling (B) Evaporator (C) Condenser (D) Throttling

Last Answer : C) Condenser

Description : Secondary cooling circuit is a must in molten sodium cooled fast breeder reactor for (A) Achieving high degree of superheat in the steam (B) Faster heat removal rate from the core (C) ... circulation pressure (D) Avoiding the mixing of water with radioactive sodium, as it may cause explosion

Last Answer : (D) Avoiding the mixing of water with radioactive sodium, as it may cause explosion

Description : The steam ejector is used to (A) Remove condensate from the steam pipelines (B) Create vacuum (C) Superheat the steam (D) None of these

Last Answer : (B) Create vacuum

Description : One kilogram of water at 0°C is changed to superheated steam of one atm pressure and 300° C. The major heat consumption in the process will be to (A) Heat the water from 0°C to 100°C (B) Evaporate the water (C) To superheat the steam (D) Data insufficient, can't be predicted

Last Answer : (B) Evaporate the water

Description : The efficiency of superheat Rankine cycle is higher than that of simple Rankine cycle because [GATE-2002] (a) The enthalpy of main steam is higher for superheat cycle (b) The mean temperature of heat ... temperature of steam in the condenser is high (d) The quality of stem in the condenser is low 

Last Answer :  (b) The mean temperature of heat addition is higher for superheat cycle  

Description : Water hammer is caused in steam carrying pipelines, because of (A) Partial condensation of steam (B) Vibration of the pipeline (C) High degree of superheat of steam (D) Its exposure to torrential rain

Last Answer : (A) Partial condensation of steam

Description : Define i)Dryness fraction ii) Degree of superheat

Last Answer : i)Dryness fraction: Dryness fraction is defined ratio of the mass of the dry steam present in the total mass of steam.  Or  Dryness fraction is ratio of the mass of actual dry ... Superheated Steam and the saturation temperature correspondingly to given pressure is said to be Degree of Superheat. 

Description : Define dry ness fraction and degree of superheat. 

Last Answer : Dryness fraction: It is defined as a fraction of dry steam that is present in a liquid vapour is called dryness fraction. Or  Dryness fraction is the ratio of the Mass of actual dry ... the temperature of superheated steam and saturated steam (Tsup - Tsat) is known as degree of superheat.

Description : What happens If a large amount of lubricant is removed from a system during refrigerant recovery?

Last Answer : the sys has too much lubricant

Description : What EPA rules require capture. of 80 of the refrigerant from a small appliance sealed system with a non-operating comprerssor if technicians are using?

Last Answer : Feel Free to Answer

Description : If an hfc-134a AC system still has pressure after the first refrigerant recovery process is complete additional recovery is necessary until the system vacuum level remains stable for?

Last Answer : 5

Description : If an hfc-134a AC system still has pressure after the first refrigerant recovery process is complete additional recovery is necessary until the system vacuum level remains stable for?

Last Answer : 5

Description : The condition of refrigerant before entering the expansion or throttle valve, in a vapour compression system (a) dry vapour (b) wet vapour (c)liquid-vapour mixture (d) high pressure saturated liquid

Last Answer : Ans: d

Description : Aqua ammonia is used as refrigerant in the following type of refrigeration system (a) compression (b) direct (c) indirect (d) absorption

Last Answer : Ans: d

Description : A certain refrigerating system has a normal operating suction pressure of 10 kg/cm gauge and condensing pressure ofabout 67 kg/cm. The refrigerant used is (a) Ammonia (b) Carbon dioxide (c) Freon (d) Brine

Last Answer : Ans: b

Description : Highest pressure encountered in a refrigeration system should be (a) critical pressure of refrigerant (b) much below critical pressure (c) much above critical pressure (d) near critical pressure

Last Answer : Ans: b

Description : Absorption system normally uses the following refrigerant (a) Freon-11 (b) Freon-22 (c) C02 (d) ammonia.

Last Answer : Ans: e

Description : In refrigerator, liquid receiver is required between condenser and flow controlling device, if quantity of refrigerant for system is (a) less than 2 kg (b) more than or equal to 3.65 kg (c) more than 10 kg (d) there is no such consideration

Last Answer : Ans: b

Description : Which of the following situations can be approximated to a steady state heat transfer system? (A) A red hot steel slab (having outside surface temperature as 1300°C) exposed to the atmospheric air at ... flowing at the rate of 6 Kg/minute through a copper pipe exposed to atmospheric air at 35°C

Last Answer : (B) 10 kg of dry saturated steam at 8 kgf/cm2 flowing through a short length of stainless steel pipe exposed to atmospheric air at 35°C

Description : Which of the following is a widely used refrigerant in vapour compression refrigeration system (using large centrifugal compressor)? (A) Freon (B) Liquid sulphur dioxide (C) Methyl chloride (D) Ammonia

Last Answer : (A) Freon

Description : The most important consideration, while designing the refrigeration system of an aircraft is that the refrigeration system (A) Is as light as possible (B) Has very high C.O.P. (C) Employs minimum quantity of refrigerant (D) Consumer minimum horse power

Last Answer : (A) Is as light as possible

Description : The benchmarking parameter for a vapour compression refrigeration system is a) kW / kg of refrigerant used b) kcal / m3 of chilled water c) BTU / Ton of Refrigeration d) kW / Ton of Refrigeration

Last Answer : d) kW / Ton of Refrigeration

Description : How much will the total cost be to replace the complete evaporator unit (fan and coil) in a central air system?

Last Answer : 5 T, you’re looking at between 5 and 7 grand depending on the exact model of the system and the cost of installation. My neighbor just had this done. You might be able to get it for less but it’s probably going to be expensive any way you slice it.

Description : . A dilute aqueous solution is to be concentrated in an evaporator system. High pressure steam is available. Multiple effect evaporator system is employed, because (A) Total heat transfer area of ... in a single effect is much lower than that in any effect in a multi-effect system

Last Answer : (B) Total amount of vapor produced per Kg of feed steam in a multiple effect system is much higher than in a single effect

Description : What is the steam economy in case of a single effect evaporator system? (A) 1 (B) > 1 (C) < 1 (D) 0.1

Last Answer : (C) < 1

Description : . An evaporator while concentrating an aqueous solution from 10 to 40% solids evaporates 30000 kg of water. The amount of solids handled by the system in kg is (A) 4000 (B) 9000 (C) 4600 (D) 3000

Last Answer : (A) 4000

Description : In a single evaporator system, the steam economy __________ by creating vacuum in the evaporator. (A) Increases (B) Decreases (C) Remain constant (D) May increase or decrease, depends on the vacuum

Last Answer : (A) Increases

Description : Pick out the wrong statement. (A) The value of hydrostatic head increases with increase in vacuum in the effect in a multiple effect evaporator system (B) Entering velocity of the liquid in ... a multiple effect evaporation system, the number of effects is limited by the total boiling point rise

Last Answer : (C) Duhring's plot is used for calculating the concentration of solution

Description : The effect of changing the evaporator temperature on COP as compared to that of changing the condenser temperature (in vapour compression refrigeration system) is (A) Less pronounced (B) More pronounced (C) Equal (D) Data insufficient, can't be predicted

Last Answer : (B) More pronounced

Description : In vapour compression refrigeration system, if the evaporator temperature and the condenser temperatures are -13°C and 37°C respectively, the Carnot COP will be (A) 5.2 (B) 6.2 (C) 0.168 (D) Data insufficient, can't be found out

Last Answer : A) 5.2

Description : Would using an old refrigerator that takes blocks of Ice as the refrigerant be better for any reason?

Last Answer : Energy is still used. That ice has to come from somewhere and then it has to be delivered.

Description : Who does online testing for Refrigerant CFC certicate?

Last Answer : Need Answer

Description : What is the best refrigerant gas?

Last Answer : Best refrigerant gas is R-290 and R600A because of its low environmental impact and excellent thermodynamics performance.

Description : Is freon Refrigerant Harmful to the environment?

Last Answer : Of course it is . Freon is a chlorofluorocarbons that causes depletion of ozone.Freon contains number of halo products like chlorine ,hydrogen bromine etc. Refrigerators are powerful source of these ... house which is causing increased temperature on earth sea level rising .ice depletion etc.

Description : How do i check the refrigerant level of my car AC?

Last Answer : To perfectly check your AC level you need to understand the components that makes up the unit such as compressor, condenser, evaporator. But the simplest method is to check if the air coming out ... use of gauge to check the air pressure from compressor but this needs a more expertise experience.