Fibre glass insulation can be used up to temperature of (A) 60°C (B) 80°C (C) 130°C (D) 180°

1 Answer

Answer :

Fibre glass insulation can be used up to temperature of 130°C

Related questions

Description : Part of the insulation of practically all electrical machinery is in the form of organic compounds which contain some amount of ______________. A. asbestos B. water C. fibre D. plastic

Last Answer : Answer: B

Description : Polyurethane cannot be used to make (A) Automobile cushion (B) Thermal insulation in refrigerator (C) Coating and adhesive (D) Fibre reinforced plastic (FRP)

Last Answer : (D) Fibre reinforced plastic (FRP)

Description : In a heat treatment shop, steel components are heat-treated in batches of 80 Tons. The  heat treatment cycle is as follows;  Increase temperature from 30 OC to 850 OC in 3 hours.  ... efficiency of 80%, for same requirement. The investment towards installation of  the new furnace is Rs. 50

Last Answer : Quantity of steel treated per batch - 80 Tons a. Efficiency of Furnace: Useful heat supplied to steel - 80000 x 0.12 x (850 - 30)   = 7872000 kcal/batch .1 mark Total heat ... = Rs. 64400/batch Efficiency of new LPG furnace - 80% Heat supplied in new LPG furnace - 7872000/0.8

Description : Pick up the correct statement from the following: (A) Plastics have generally low melting point (B) The coefficient of thermal expansion of plastics is about three times than that of steel (C) ... fibre-glass with phenolic resins has absorption coefficient of about 0.67 (D) All the above

Last Answer : Answer: Option D

Description : Which type of glass is used for making glass reinforced plastic? (1) Pyrex glass (2) Flint glass (3) Quartz glass (4) Fibre glass

Last Answer : (4) Fibre glass Explanation: Fiberglass is a lightweight, extremely strong, and robust material. Although strength properties are somewhat lower than carbon fiber and it is less stiff, the material ... also very favorable when compared to metals, and it can be easily formed using molding processes.

Description : Which of the following is the most widely used insulating material for steam carrying pipelines? (A) Ceramic fibre blanket (B) Glass wool and 85% magnesia (C) Vermiculite (D) Slag wool

Last Answer : (B) Glass wool and 85% magnesia

Description : Choose the optical fibre material from the given materials. a) Glass b) Plastic c) Silica d) Quartz

Last Answer : c) Silica

Description : Pick out the correct statement. (A) Noise from ball mills can be dealt with by fibre glass lined enclosures (B) Noise from vibrating chutes can be reduced by lining the metallic chute with rubber (C) Noise ... cloth conveyor belts and rubber/plastic covered metallic rollers (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Type of glass used in optical work is the __________ glass. (A) Soda-lime (B) Fibre (C) Lead (D) Borosilicate

Last Answer : (C) Lead

Description : Which glass is usually used in optical work? (A) Lead glass (B) High silica (borosilicate) glass (C) Photo-sensitive glass (D) Fibre glass

Last Answer : (C) Photo-sensitive glass

Description : Fibre reinforced plastic (FRP) are (A) Made of glass fibre and thermoplastic resins (B) Anisotropic (C) Made of thermosetting resin and glass fibre (D) Both 'b' & 'c'

Last Answer : Option D

Description : Fibre glass (A) Retains heat-longer (B) Has a higher strength to weight ratio (C) Is shock proof and fire retardant (D) All the above

Last Answer : Answer: Option D

Description : Which type of glass is used for making glass reinforced plastic? (1) Pyrex glass (2) Flint glass (3) Quartz glass (4) Fibre glass

Last Answer : Fibre glass

Description : Which of the listed groups of electrical insulation materials is best suited for the highest operating temperatures? A. impregnated cotton and silk B. unimpregnated paper and cotton C. pure glass and quartz D. mica and porcelain with bonding agents

Last Answer : Answer: C

Description : Bakelite (phenol-formaldehyde) resin cannot be used as (A) Decorative paint (B) Decorative laminates (C) Electrical insulation (D) Glass reinforced plastics

Last Answer : (A) Decorative paint

Description : What stripping tool would NOT be used to strip glass braid insulation?

Last Answer : Hot-blade stripper.

Description : Which of the following structures or regions is incorrectly paired with its functions? (a) Medulla : Controls respiration oblongata and cardiovascular reflexes (b) Limbic : Consists of fibre tracts ... thirst (d) Corpus callosum : Band of fibers connecting left and right cerebral hemispheres

Last Answer : (b) Limbic : Consists of fibre tracts system that interconnect different regions of brain controls movement

Description : An increase in temperature on the top fibre of a simply supported beam will cause (a) Downward deflection (b) Upward deflection (c) No deflection (d) Angular rotation about neutral axis

Last Answer : Upward deflection

Description : Which of the following structures or regions is incorrectly paired with its function ? (1) Medulla oblongata : controls respiration and cardiovascular reflexes. (2) Limbic system : consists of fibre ... and thirst. (4) Corpus callosum : band of fibers connecting left and right cerebral hemispheres.

Last Answer : (2) Limbic system : consists of fibre tracts that interconnect different regions of brain; controls movement.

Description : In preparing to take insulation resistance readings on a main generator, the windings should be grounded for about 15 minutes prior to the test to _____________. A. allow accurate zeroing of the meter ... the windings D. help the windings to cool to the same temperature as the ground test connection

Last Answer : Answer: C

Description : Which of the conditions listed will indicate the need to clean the insulation on the windings of an electric motor? A. Higher than normal operating temperature. B. Excessive vibration at normal speed. C. Sparking at the brushes. D. High megger readings.

Last Answer : Answer: A

Description : Which of the listed conditions could indicate the need for cleaning electrical insulation? A. Low ambient temperature B. Low operating temperature C. High dielectric strength D. Low megger readings

Last Answer : Answer: D

Description : Which of the listed classes of electrical insulation is suited for the highest operating temperature? A. Class 90 (O) B. Class 105 (A) C. Class 130 (B) D. Class 180 (H)

Last Answer : Answer: D

Description : The need for insulation cleaning may be determined by _____. A. visual inspection for dirt accumulation B. high megger readings C. low operating temperature D. the time period since the last cleaning

Last Answer : Answer: A

Description : Electrical insulation is classed by the _____________. A. International Association of Electrical Manufacturers B. approximate operating voltage and current expected C. U.S. Coast Guard D. temperature stability of the manufacturing material(s)

Last Answer : Answer: D

Description : The life expectancy of electrical insulation, is approximately halved for an increased operating temperature of _______________. A. 10°C B. 25°C C. 50°C D. 100°C

Last Answer : Answer: A

Description : The existing resistance of a conductor is dependent upon its length, cross-sectional area, _____________. A. temperature and insulation B. material and insulation C. resistive coefficient and material D. material and temperature

Last Answer : Answer: D

Description : When the current flow through a copper wire increases, its _____________. A. resistance will decrease B. insulation will burn C. temperature will increase D. conductivity will increase

Last Answer : Answer: C

Description : Routine maintenance of dry-type transformers should include ____________. A. cleaning the windings, if accessible, with a vacuum cleaner or very low pressure air B. measuring and recording the winding ... . making sure that the units are close to bulkheads or corners to protect them from damage

Last Answer : Answer: A

Description : You are testing the insulation in an AC generator with a megohmeter. The resistance value of a dry, clean winding will ____________. A. continue to rise as the test potential is maintained, ... fairly steady after 5 to 7 minutes D. stabilize after approximately 2 to 4 minutes of fluctuation

Last Answer : Answer: A

Description : An insulation resistance test is performed on a particular piece of electric equipment. In addition to the resistance reading, what information listed below should be entered in the electrical log? A. ... D. The complete nameplate data from the resistance test instrument used to obtain the reading.

Last Answer : Answer: B

Description : What are the necessary tests to determine the efficiency, voltage regulation, and temperature rise of winding & insulation of transformer?

Last Answer : 1.Direct loading test 2.Open circuit test 3. Short circuit test 4. Sumpner's or back to back test

Description : Thermocol (expanded polystyrene) is not used for (A) Low temperature thermal insulation as in refrigerator and air conditioners (B) Acoustic control and ceiling for building (C) High temperature thermal insulation in furnaces (D) Packing of delicate electronic gadgets

Last Answer : (C) High temperature thermal insulation in furnaces

Description : For a given ambient air temperature with increase in the thickness of insulation of a hot cylindrical pipe, the rate of heat loss from the surface would (A) Decrease (B) Increase (C) First decrease and then increase (D) First increase and then decrease

Last Answer : (D) First increase and then decrease

Description : What is the life insulation if temperature increased by 10°C?

Last Answer : The life of the machine insulation decreases by half if the temperature of the insulation increases by 10°C.

Description : A steam pipe is intended to be insulated with two layers of insulating materials of different thermal conductivities. For minimum heat transfer to take place (A) The better insulation material should be put just ... to which insulating material is to be put inside (i.e., just next to the pipe)

Last Answer : (A) The better insulation material should be put just next to pipe (i.e., inside)

Description : Due to which of the following reasons the cables should not be operated too hot ? (a) The oil may loose its viscosity and it may start drawing off from higher levels (b) Expansion of the ... instability may rise due to the rapid increase of dielectric losses with temperature (e) All of the above

Last Answer : (e) All of the above

Description : Solid type cables are considered unreliable beyond 66 kV because (a) insulation may melt due to higher temperature (b) skin effect dominates on the conductor (c) of corona loss between conductor and sheath material (d) there is a danger of breakdown of insulation due to the presence of voids

Last Answer : (d) there is a danger of breakdown of insulation due to the presence of voids

Description : Indicate the three types oftransmissionline energylosses. a. I2R, R , and temperature b. Radiation, I2R, and dielectric heating c. Dielectric separation, insulation breakdown, and radiation d. Conductor heating, dielectric heating, and radiation resistance.

Last Answer : b. Radiation, I2R, and dielectric heating

Description : What happens to insulation when temperature rises?

Last Answer : For insulators, an increase in temperature will cause their resistance to decrease -which is why excessive temperature is often the main reason why insulation fails