In industrial operations fluids with temperature less than __________ are set as the limit for waste heat
recovery because of the risk of condensation of corrosive liquids
a. 80C
b. 100C
c. 120C
d. 200C

1 Answer

Answer :

100C

Related questions

Description : Leidenfrost point is a term concerned with the (A) Condensation of the saturated vapor on a cold surface (B) Concentration of a corrosive solution by evaporation (C) Heat transfer between two highly viscous liquids (D) Boiling of a liquid on a hot surface

Last Answer : (D) Boiling of a liquid on a hot surface

Description : Design of waste heat boiler for recovery of waste heat from furnace gases depends upon the (A) Quantity & temperature of waste gas (B) Dust concentration & nature of dust in waste gas (C) Corrosive nature of the waste gas (D) All (A), (B) and (C)

Last Answer : (B) Dust concentration & nature of dust in waste gas

Description : Techniques of waste heat recovery ....... a) Direct contact condensation b) Indirect contact condensation c) Transport membrane condensation d) All of the above

Last Answer : All of the above

Description : A waste heat recovery system in industrial process has been key to reduce ....... Consumption. a) Coal b) Fuel c) Biogas d) Oil

Last Answer : Fuel

Description : Using an organic fluid that boils at a low temperature means that energy could be regeneratedfrom waste fluids is known as ________. a) Heat exchanger b) Heat remover c) Heat pumps d) Heat absorber

Last Answer : Heat pumps

Description : Pick out the wrong statement. (A) Packed towers are preferred for vacuum operation, because the pressure drop through the packing is less and they (packings) also lessen the ... of liquid, problem of channelling, loading & flooding is generally encountered in packed towers

Last Answer : (C) Diameter of randomly packed tower is normally more than 1.2 metres

Description : Condensing film co-efficient for steam on horizontal tubes ranges from 5000 to 15000 Kcal/hr.m2 .°C. Condensation of vapor is carried out inside the tube in a shell and tube heat ... drop through the exchanger is desired (D) Temperature of the incoming vapor is very high

Last Answer : (B) Supersaturated

Description : A high temperature waste heat recovery unit consists of recovering waste heat at temperaturesgreater than _______. a) 200 °C b) 500 °C c) 300 °C d) 400 °C

Last Answer : 400 °C

Description : Metallic recuperators are not used for waste heat recovery, if the hot flue gas temperature is above __________ °C, because corrosion prevails at higher temperatures. (A) 350 (B) 750 (C) 1050 (D) 1250

Last Answer : (B) 750

Description : Calculate the recoverable waste heat (Q, in kCal/hour) from flue gases using the followingparameters: V (flow rate of the substance) 2000 m3/hr r (density of the flue gas): 0.9 kg/m3 Cp (specific heat ... (temperature difference): 120 oC h (recovery factor): 50% a. 21600 b. 43200 c. 25600 d. 34000

Last Answer : 21600

Description : A waste heat recovery unit (WHRU) is an_________ that transfers heat from process outputs at high temperature to another part of the process for some purpose, usually increased efficiency. a) Energy recovery heat exchanger b) Energy recovery heat diffuser c) Both ‘a’ and ‘b’ d) None of the above

Last Answer : Energy recovery heat exchanger

Description : A waste heat recovery unit is an energy recovery heat exchanger that transfers heat from process outputs at ........ a) High temperature b) Medium temperature c) Low temperature d) Both a & b

Last Answer : High temperature

Description : Nellore to medium temperature waste heat recovery system the most suitable device is ------ a) Economizer b) Heat wheels c) Air preheater d) Recuperate d) Carbonate

Last Answer : Heat wheels

Description : In a low to medium temperature waste heat recovery system which of the device is most suitable a) Economiser b) Heat wheels c) air preheater d) Recuperator

Last Answer : Heat wheels

Description : The damage/deterioration of metals by the __________ action of fluids is called 'erosion'. (A) Abrasive (B) Corrosive (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (A) Abrasive

Description : Diaphragm valves are used for handling __________ fluids. (A) Corrosive (B) Viscous (C) Non-Newtonian (D) Solid suspended

Last Answer : (A) Corrosive

Description : Explain with reason through which side of shell and tube heat exchanges, the following liquids are directed. (i) viscous liquid (ii) high pressure liquid (iii) corrosive liquid

Last Answer : Viscous liquid : Viscous liquid is passed through shell side Reason: because of the presence of baffles in the shell induce turbulence and hence increases heat transfer rate. High pressure liquid: High ... To avoid expensive alloy shells (in order to save the cost of expensive material for shell).

Description : Agitated film evaporator is suitable for concentrating __________ liquids. (A) Foaming (B) Viscous (C) Very thin (D) Corrosive

Last Answer : (B) Viscous

Description : Mark the correct option a) There is no maximum limit of deposit in TD accounts of any type b) No subsequent withdrawal allowed in TD accounts before date of maturity c) The investment under 5 years TD ... the benefit of Section 80C f the income tax Act 1961 from 01-04-2007 d) All the above

Last Answer : d) All the above

Description : What are the benefits or the advantages of waste heat recovery units (WHRU)? a) Reduced Pollution b) Reduced equipment sizes c) Reduced auxiliary energy consumption. d) All of the above

Last Answer : All of the above

Description : The waste heat recovery unit (WHRU) is a tool involved in _______. a) Regeneration b) Cogeneration c) Both ‘a’ and ‘b’ d) None of the above

Last Answer : Cogeneration

Description : One of the key areas for ....... energy saving in existing systems is waste heat recovery. a) Potential b) Kinetic c) Thermal d) Electrical

Last Answer : Potential

Description : A major advantage of waste heat recovery in industry is a) Reduction in pollution c) Increase efficiency d) None of the above

Last Answer : Reduction in pollution

Description : Recovery of waste heat from hot fluid to fluid is called: a) thermo compressor b) waste heat recovery boiler c) heat Pump d) economizer

Last Answer : heat Pump

Description : Recovery of heat from dryer exhaust air is a typical application of: a) Waste heat recovery boiler b) Heat pump c) Heat wheel d) Economizer

Last Answer : Heat wheel

Description : Air preheater is not used as a waste heat recovery system in a____. a) Boiler b) billet Reheating Furnace c) Heat treatment furnace d) compressor

Last Answer : compressor

Description : Recuperated is used mainly as a waste heat recovery system in a ____. a) Boiler b) Billet Reheating Furnace c) Compressor d) None of the above

Last Answer : Billet Reheating Furnace

Description : Major advantage of waste heat recovery in industry is: a) Reduction in pollution b) increase in efficiency c) Both a & b d) none of the above

Last Answer : Both a & b

Description : Which of the following is not used as a filter medium in case of corrosive liquids? (A) Nylon (B) Glass cloth (C) Metal cloth of monel or stainless steel (D) Cotton fabric

Last Answer : (D) Cotton fabric

Description : The equipment used in the extraction of highly corrosive radioactive liquids is (A) Pulse column (B) Spray column (C) Mixer settler (D) Baffle tower

Last Answer : (A) Pulse column

Description : Multiple effect evaporation is generally recommended, when the (A) Large scale evaporation of liquor is needed (B) Corrosive liquids are to be concentrated

Last Answer : (A) Large scale evaporation of liquor is needed

Description : Pitch creosote mixture (PCM) as compared to furnace oil is a better fuel, because its (A) Emissivity factor is higher (B) Sulphur content is lower (C) Flue gas has lower dew point thereby facilitating more waste heat recovery (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Investment under senior citizen savings scheme qualifies for the benefit of __________ of the Income Tax Act, 1961. A. Section 60C B. Section 70C C. Section 80C D. Section 90C E. None of the Above

Last Answer : C. Section 80C Explanation: Investment under this scheme qualifies for the benefit of Section 80C of the Income Tax Act, 1961.

Description : Traditionally, waste heat of low temperature range ________ has not been used for electricitygeneration despite efforts by ORC companies, mainly because the Carnot efficiency is rather low. a) 0-250 °C b) 0-150 °C c) 0-200 °C d) 0-120 °C

Last Answer : 0-120 °C

Description : LMTD for evaporators & condensers for a given terminal parameters & set of conditions for counter-flow is equal to that for parallel flow. In such heat exchangers, with one of the fluids condensing or evaporating, the surface ... Parallel (B) Mixed (C) Counter flow (D) Same in either 'a', b' or 'c'

Last Answer : (D) Same in either 'a', b' or 'c'

Description : The heat absorbed by a unit mass of a material at its holding point in order to convert the material into a gas at the same temperature.  a. Latent Heat of Sublimation  b. Latent Heat of Vaporization  c. Latent Heat of Fusion  d. Latent Heat Of Condensation

Last Answer : Latent Heat of Vaporization

Description : The SP/First class PM may grant compensation to the sender of a regd article up to a) 500 b) 200 c) 1000 d) 100

Last Answer : d) 100

Description : Cyclones are used primarily for separating (A) Solids (B) Solids from fluids (C) Liquids (D) Solids from solids

Last Answer : (B) Solids from fluids

Description : Diaphragm pumps are used to transport (A) Solids (B) Liquids (C) Fluids (D) Slurries

Last Answer : (D) Slurries

Description : Extremely large or small volumes of fluids are generally best routed through the shell side of a shell and tube heat exchanger, because of the (A) Less corrosion problems (B) Flexibility possible in the baffle arrangement (C) Low pressure drop (D) High heat transfer co-efficient

Last Answer : (B) Flexibility possible in the baffle arrangement

Description : Heat recovery equipment will be most effective when the temperature of flue gas is: a) 250oC b) 200 oC c)400 oC d) 280 oC

Last Answer : 400 oC

Description : Limit of BOD prescribed by Central Pollution Control Board for the discharge of industrial and muncipal waste water into natural surface water:

Last Answer : Limit of BOD prescribed by Central Pollution Control Board for the discharge of industrial and muncipal waste water ... C. lt 30 ppm D. lt 100 ppm

Description : Limit of BOD prescribed by Central Pollution Control Board for the discharge of industrial and muncipal waste water into natural surface water:

Last Answer : Limit of BOD prescribed by Central Pollution Control Board for the discharge of industrial and muncipal waste water into ... `lt` 3 ppm D. `lt` 10 ppm

Description : Composite property applicable to all fluids  a. Entropy  b. Enthalpy  c. Specific Heat  d. None of the above

Last Answer : Enthalpy

Description : What kind of car was KAR-120C? (The Prisoner)

Last Answer : Lotus 7, here is the link to the KAR-120C Great car, goes and stops.

Description : What kind of car was KAR-120C? (The Prisoner)

Last Answer : Lotus 7, here is the link to the KAR-120C Great car, goes and stops.

Description : What state of matter water takes this form above 100c?

Last Answer : Feel Free to Answer

Description : When heated from 00 to 100C volume of a given mass of water will : (1) Increase gradually (2) Decrease gradually (3) Increase and then will decrease (4) Decrease and then will increase

Last Answer : Decrease and then will increase

Description : In a gas-liquid shell and tube heat exchanger, the (A) Presence of a non-condensable gas decreases the condensing film co￾efficient (B) Gases under high pressure are routed through the tube side, because high pressure ... water or steam condensate remain localised to the tubes (D) All 'a', 'b' & 'c'

Last Answer : (D) All 'a', 'b' & 'c'

Description : In which of the waste heat recovery equipment, the flow of flue gas and air is alternately reversed after a fixed interval of time? (A) Recuperator (B) Regenerator (C) Waste heat boiler (D) None of these

Last Answer : (B) Regenerator