The waste heat recovery unit (WHRU) is a tool involved in _______.
a) Regeneration
b) Cogeneration
c) Both ‘a’ and ‘b’
d) None of the above

1 Answer

Answer :

Cogeneration

Related questions

Description : A waste heat recovery unit (WHRU) is an_________ that transfers heat from process outputs at high temperature to another part of the process for some purpose, usually increased efficiency. a) Energy recovery heat exchanger b) Energy recovery heat diffuser c) Both ‘a’ and ‘b’ d) None of the above

Last Answer : Energy recovery heat exchanger

Description : What are the benefits or the advantages of waste heat recovery units (WHRU)? a) Reduced Pollution b) Reduced equipment sizes c) Reduced auxiliary energy consumption. d) All of the above

Last Answer : All of the above

Description : A high temperature waste heat recovery unit consists of recovering waste heat at temperaturesgreater than _______. a) 200 °C b) 500 °C c) 300 °C d) 400 °C

Last Answer : 400 °C

Description : A waste heat recovery unit is an energy recovery heat exchanger that transfers heat from process outputs at ........ a) High temperature b) Medium temperature c) Low temperature d) Both a & b

Last Answer : High temperature

Description : Major advantage of waste heat recovery in industry is: a) Reduction in pollution b) increase in efficiency c) Both a & b d) none of the above

Last Answer : Both a & b

Description : In industrial operations fluids with temperature less than __________ are set as the limit for waste heat recovery because of the risk of condensation of corrosive liquids a. 80C b. 100C c. 120C d. 200C

Last Answer : 100C

Description : Calculate the recoverable waste heat (Q, in kCal/hour) from flue gases using the followingparameters: V (flow rate of the substance) 2000 m3/hr r (density of the flue gas): 0.9 kg/m3 Cp (specific heat ... (temperature difference): 120 oC h (recovery factor): 50% a. 21600 b. 43200 c. 25600 d. 34000

Last Answer : 21600

Description : One of the key areas for ....... energy saving in existing systems is waste heat recovery. a) Potential b) Kinetic c) Thermal d) Electrical

Last Answer : Potential

Description : Techniques of waste heat recovery ....... a) Direct contact condensation b) Indirect contact condensation c) Transport membrane condensation d) All of the above

Last Answer : All of the above

Description : A waste heat recovery system in industrial process has been key to reduce ....... Consumption. a) Coal b) Fuel c) Biogas d) Oil

Last Answer : Fuel

Description : Nellore to medium temperature waste heat recovery system the most suitable device is ------ a) Economizer b) Heat wheels c) Air preheater d) Recuperate d) Carbonate

Last Answer : Heat wheels

Description : A major advantage of waste heat recovery in industry is a) Reduction in pollution c) Increase efficiency d) None of the above

Last Answer : Reduction in pollution

Description : Recovery of waste heat from hot fluid to fluid is called: a) thermo compressor b) waste heat recovery boiler c) heat Pump d) economizer

Last Answer : heat Pump

Description : Recovery of heat from dryer exhaust air is a typical application of: a) Waste heat recovery boiler b) Heat pump c) Heat wheel d) Economizer

Last Answer : Heat wheel

Description : In a low to medium temperature waste heat recovery system which of the device is most suitable a) Economiser b) Heat wheels c) air preheater d) Recuperator

Last Answer : Heat wheels

Description : Air preheater is not used as a waste heat recovery system in a____. a) Boiler b) billet Reheating Furnace c) Heat treatment furnace d) compressor

Last Answer : compressor

Description : Recuperated is used mainly as a waste heat recovery system in a ____. a) Boiler b) Billet Reheating Furnace c) Compressor d) None of the above

Last Answer : Billet Reheating Furnace

Description : In which of the waste heat recovery equipment, the flow of flue gas and air is alternately reversed after a fixed interval of time? (A) Recuperator (B) Regenerator (C) Waste heat boiler (D) None of these

Last Answer : (B) Regenerator

Description : Metallic recuperators are not used for waste heat recovery, if the hot flue gas temperature is above __________ °C, because corrosion prevails at higher temperatures. (A) 350 (B) 750 (C) 1050 (D) 1250

Last Answer : (B) 750

Description : Thermal efficiency of furnaces can be improved by (A) Waste heat recovery from flue gas (B) Minimising heat losses from furnace walls (C) Maintaining proper draught (D) All (A), (B) and (C

Last Answer : (D) All (A), (B) and (C

Description : To reduce the stack loss, heat recovery from flue gas can be done by (A) Preheating of cold stock (B) Preheating of combustion air (C) Steam generation in waste heat boilers (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Regenerators are used for waste heat recovery in (A) By-product coke ovens (B) Beehive coke oven (C) Blast furnace stoves (D) Soaking pits

Last Answer : (A) By-product coke ovens

Description : Heat transfer rate to the stock/charge in the furnace does not depend upon the (A) Emissivity of the refractory walls (B) Size of the furnace (C) Use of waste heat recovery equipments (D) Thickness of the stock

Last Answer : (C) Use of waste heat recovery equipments

Description : Design of waste heat boiler for recovery of waste heat from furnace gases depends upon the (A) Quantity & temperature of waste gas (B) Dust concentration & nature of dust in waste gas (C) Corrosive nature of the waste gas (D) All (A), (B) and (C)

Last Answer : (B) Dust concentration & nature of dust in waste gas

Description : Which of the following is not a continuous waste heat recovery equipment from the flue gases going out of furnace? (A) Economiser (B) Regenerator (C) Ceramic recuperator (D) Waste heat boiler

Last Answer : (B) Regenerator

Description : Pitch creosote mixture (PCM) as compared to furnace oil is a better fuel, because its (A) Emissivity factor is higher (B) Sulphur content is lower (C) Flue gas has lower dew point thereby facilitating more waste heat recovery (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Define the term waste heat recovery?

Last Answer : Waste heat is the heat which is not at all used and exhausted out as a waste product. Waste heat is normally available from the industry in the form of process steam and water at high ... industries. This heat can be recovered for useful purpose. This process is known-as waste heat recovery.

Description : Define The Term Waste Heat Recovery?

Last Answer : Waste heat is the heat which is not at all used and exhausted out as a waste product. Waste heat is normally available from the industry in the form of process steam and water at high ... industries. This heat can be recovered for useful purpose. This process is known as waste heat recovery.

Description : Benefits of Waste Heat Recovery a. Reduction in pollution b. Reduction in equipment sizes c. Reduction in auxiliary energy consumption d. All of the above

Last Answer : Ans:- d. All of the above

Description : Waste heat Recovery system

Last Answer : Waste heat Recovery system Waste heat is energy that is rejected to the environment. It arises from equipment and operating inefficiencies, as well as from thermodynamic limitations on equipment and ... to minimize these costs, and to reduce environmental impact along with several other benefits.

Description : The ideal efficiency of a Brayton cycle with regeneration, with increase in pressure ratio will  (a) increase  (b) decrease  (c) remain unchanged  (d) increase/decrease depending on ap-plication  (e) unpredictable. “

Last Answer : Answer : b

Description : The ideal efficiency of a Brayton cycle without regeneration with increase ni pressure ratio will  (a) increase  (b) decrease  (c) remain unchanged  (d) increase/decrease depending on application  (e) unpredictable.

Last Answer : Answer : a

Description : The informative labels affixed _______. A) Product. C) equipment B) tool. D) machine .

Last Answer : product

Description : State the factor governing the selection of cogeneration system. write advantages of cogeneration.

Last Answer : Factor governing the selection of cogeneration system: 1) electrical load matching 2) thermal load matching 3) Electrical load matching 4) Thermal load matching 5)Thermal to electrical energy ratio ... Very high efficiency. 4) Reduction in emission of pollutants due to reduced fuel consumption. 

Description : Write factors used for governing the selection of cogeneration system and state the advantages of cogeneration.

Last Answer : Factor governing the selection of cogeneration system: 1) electrical load matching 2) thermal load matching 3) Electrical load matching 4) Thermal load matching 5)Thermal to electrical energy ... ) Very high efficiency. 4) Reduction in emission of pollutants due to reduced fuel consumption.

Description : State the advantages of cogeneration. 

Last Answer : Advantages of co-generation: 1) Co-generation can meet both power & heat requirements. 2) Less cost than conventional generation. 3) Higher system efficiency due to energy wastage is highly ... reduces due to cogeneration plant is located in same premises. 10) It can maintain grid stability 

Description : State and explain the factors that govern the selection of cogeneration system for an industry.

Last Answer : The factors that govern the selection of cogeneration system for an industry: The factors that govern the selection of cogeneration systems are very much site/situation specific. The local factors ... require is generated. If required energy demand is higher electricity purchased from grid. 

Description : State the advantages of adoption of cogeneration system in an industry.

Last Answer : The advantages of adoption of cogeneration system in an industry: 1) Co-generation can meet both power & heat needs. 2) Less costly. 3) Very high efficiency. 4) Reduction in ... . 8) Due to decentralization of electricity it avoids transmission losses & makes system more efficient.

Description : State the need of cogeneration in present scenario.

Last Answer : Need for co-generation in present scenario: 1. In conventional power plant efficiency is only 35% & remaining 65% of energy is lost. 2. The conventional system uses energy of fuel ... economical solution to energy shortages. 4. Increases financial capital. 5. Increases environmental value. 

Description : Heat recovery provides valuable energy sources and ....... consumption. a) Reduce energy b) Increase energy c) Increase fuel d) Reduce fuel

Last Answer : Reduce energy

Description : Energy recovery is typically via production of ____ a) Gas b) Heat c) Light d) Steam

Last Answer : Steam

Description : Heat recovery equipment will be most effective when the temperature of flue gas is: a) 250oC b) 200 oC c)400 oC d) 280 oC

Last Answer : 400 oC

Description : Increase the output of work per unit time c) Automatic tool. c) manual tool d) Implement tool. d) matching tool

Last Answer : manual tool

Description : In a Rankine cycle, regeneration results in higher efficiency because (a) Pressure inside the boiler increases [GATE-2003] (b) Heat is added before steam enters the low pressure turbine (c) ... temperature of heat addition in the boiler increases (d) Total work delivered by the turbine increases 

Last Answer : (c) Average temperature of heat addition in the boiler increases  

Description : Types of waste heat exchanger are: a) Regenerative and recuperative burners b) Economizers c) Waste heat boilers d) All of the above

Last Answer : All of the above

Description : Traditionally, waste heat of low temperature range ________ has not been used for electricitygeneration despite efforts by ORC companies, mainly because the Carnot efficiency is rather low. a) 0-250 °C b) 0-150 °C c) 0-200 °C d) 0-120 °C

Last Answer : 0-120 °C

Description : Using an organic fluid that boils at a low temperature means that energy could be regeneratedfrom waste fluids is known as ________. a) Heat exchanger b) Heat remover c) Heat pumps d) Heat absorber

Last Answer : Heat pumps

Description : The waste heat energy could be used to produce ....... a) Cool air b) Hot air c) Exhaust gas d) All of the above

Last Answer : Cool air

Description : The biggest point sources of waste heat originate from ....... production. a) Steel or Brass b) Copper or Glass c) Steel or Glass d) Steel or Copper

Last Answer : Steel or Glass

Description : In 1976, Congress enacted the Resource Conservation and Recovery Act designed to protect public health and the environment from improper management of hazardous waste. The Resource Conservation and Recovery Act categorizes hazardous wastes into four groups. Identify three of the four groups. 

Last Answer : ANSWER: TOXIC (POISONOUS), REACTIVE, IGNITABLE, AND CORROSIVE