A negative sequence relay is commonly used to protect 

(A) an alternator (B) an transformer (C) a transmission line (D) a bus bar

1 Answer

Answer :

A negative sequence relay is commonly used to protect  an alternator

Related questions

Description : A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

Last Answer : A negative sequence relay is used for protection of Generator 

Description : The transmission line distance protection relay having the property of being inherently directional is (A) impedance relay (B) MHO relay (C) OHM relay (D) reactance relay

Last Answer : The transmission line distance protection relay having the property of being inherently directional is MHO relay

Description : If the fault current is 2000 A, the relay setting is 50% and CT ratio is 400:5, the plug setting multiplier will be

Last Answer : If the fault current is 2000 A, the relay setting is 50% and CT ratio is 400:5, the plug setting multiplier will be 10 A

Description : A reactance relay is (A) Voltage restrained directional relay (B) Directional restrained over-current relay (C) Voltage restrained over current relay (D) Directional restrained over voltage relay

Last Answer : A reactance relay is Directional restrained over-current relay

Description : What is the time of operation of a relay of rating 5 amp 2.2 sec, IDMT and having a relay of setting of 125% Tms = 0.6 It is connected to a supply circuit through a CT, 400 ratio. The fault current is 400 amp.

Last Answer : 1.92 sec is the time of operation of a relay of rating 5 amp 2.2 sec, IDMT and having a relay of setting of 125% Tms = 0.6 It is connected to a supply circuit through a CT, 400 ratio. The fault current is 400 amp.

Description :  A power system is subjected to a fault which makes the zero sequence component of current equal to zero. The nature of fault current is: A) Double line to ground fault B) Line to line fault C) Line to ground fault D) Three-phase to ground fault

Last Answer :  A power system is subjected to a fault which makes the zero sequence component of current equal to zero. The nature of fault current is: Line to line fault

Description : The zero sequence current of a generator for line to ground fault is j 2.4 p.u. The current through the neutral during the fault is (a) j 0.8 p.u (b) j 2.4 p.u. (c) j 0.24 p.u. (d) j 7.2 p.u. 

Last Answer : j7.2

Description : The sequence components of current of a single-phase load connected to a 3-phase system are (A) equal positive and negative sequence components (B) equal positive, negative and zero sequence components (C) vector sum of sequence currents is zero (D) algebraic sum of sequence currents is zero

Last Answer : The sequence components of current of a single-phase load connected to a 3-phase system are equal positive, negative and zero sequence components

Description : An alternator has a phase sequence of RYB for its phase voltage. In case the direction of rotation of alternator is reversed, the phase sequence will become?

Last Answer : An alternator has a phase sequence of RYB for its phase voltage. In case the direction of rotation of alternator is reversed, the phase sequence will become RBY.

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Last Answer : 0

Description : Which organization in the United States studies and assesses the environment to protect it and the people affected by any negative change in the environment?

Last Answer : The Environmental Protection Agency (or EPA for short)

Description : Which of the following is correct for CD8 T cells? A- CD8 T cells only recognize virus-infected cells B- CD8 T cell receptor recognizes epitopes that are also commonly recognized by B cells ... selection only D- CD8 T cells can kill individual virus-infected cells in a contact dependent fashion

Last Answer : CD8 T cells can kill individual virus-infected cells in a contact dependent fashion

Description : Define negative sequence component.

Last Answer : It has 3 vectors equal in magnitude and displaced from each other by an angle 120 degrees and has the phase sequence in opposite to its original phasors.

Description : What is meant by positive, negative and zero sequence reactance.

Last Answer : The reactance diagram of a power system, when formed using positive, negative and zero sequence reactances are called positive, negative and zero sequence reactance diagram resp.

Description : What is meant by positive, negative and zero sequence impedance.

Last Answer : The impedance of the circuit element for positive, negative and zero sequence component currents are called positive, negative and zero sequence impedances resp.

Description : What are negative sequence components?

Last Answer : The negative sequence components of a three phase unbalanced vectors consists of three vectors of equal magnitude displaced from each other by 120 degree in phase and having the phase sequence opposite to that of the original vectors.

Description : When the negative sequence reactance arises?

Last Answer : Negative sequence arises whenever there is any unbalance present in the system. Their effect is to set up a field rotating in opposite direction to the main field.

Description : What is Negative sequence reactance?

Last Answer : Negative sequence can arise whenever there is any unbalance present in the system. Their effect is to setup a field rotating in opposite direction to the main field. 

Description : What you mean by positive sequence, negative sequence and zero sequence of voltage?

Last Answer : Positive phase sequence A system of vectors is said to have positive sequence if they are all of equal magnitude and are displaced by 120° with same time interval to arrive at fixed axis of reference ... in all the 3- phases. Such phase sequence is zero phase sequence.

Description : What is the negative sequence capability?

Last Answer : I2 = 5% max,  I2 2 t = 7

Description : Va and Vb are negative sequence component voltages the difference angle between Va and Vb with respect to Va is a) 240 b) 120 c) 180 d) 360

Last Answer : Ans: 120

Description : For which of the following protection from negative sequence currents is provided ? (a) Generators (b) Motors (c) Transmission line (d) Transformers

Last Answer : (a) Generators

Description : Explain negative phase sequence protection of alternator.

Last Answer : Negative phase sequence protection of alternator: Unbalanced loading on alternator mainly causes the negative sequence currents which generate the negative sequence components of magnetic fields. These fields ... components due to unbalance and operates the relay which further operates CB.

Description : Systems for Protection from negative sequence current is provided normally for (a) Transformers (c) Transmission lines (b) Generators (d) Motors

Last Answer : Systems for Protection from negative sequence current is provided normally for Transmission lines

Description : The inertia constant of a 100 MVA, 11 kV water wheel generator is 4. The energy stored in the rotor at the synchronous speed is: A) 400 Mega Joule B) 400 Kilo Joule C) 25 Mega Joule D) 25 Kilo Joule

Last Answer : The inertia constant of a 100 MVA, 11 kV water wheel generator is 4. The energy stored in the rotor at the synchronous speed is: 400 Mega Joule

Description : Which statement out of the following statements about ‘corona’ is incorrect? A) Corona gives rise to radio interference B) Corona results in loss of power in transmission C) Corona discharge can be observed as red luminescence D) Corona is always accompanied by a hissing voice

Last Answer : Which statement out of the following statements about ‘corona’ is incorrect? A) Corona gives rise to radio interference B) Corona results in loss of power in transmission C) Corona discharge can be observed as red luminescence D) Corona is always accompanied by a hissing voice

Description : A DC reactor is connected in series with each pole of a converter station in order to: A) prevent commutation failures in the inverter B) supply reactive power to the converter C) improve system stability D) increase the power transfer capability

Last Answer : A DC reactor is connected in series with each pole of a converter station in order to:  prevent commutation failures in the inverter

Description : The melting point of carbon is: A) 1800 degree Centigrade B) 2200 degree Centigrade C) 3500 degree Centigrade D) 5500 degree Centigrade

Last Answer : The melting point of carbon is:  3500 degree Centigrade 

Description : It is always economical to improve the power factor of an electric installation to (a) zero (b) unity (c) a little less than unity (d) a little more than unity 

Last Answer : To  a  little  less  than  unity.

Description : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, j0.1 and j0.04 respectively. The neutral of ... the fault is  (A) 513.8 V (B) 889.9 V (C) 1112.0 V (D) 642.2 V

Last Answer : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, ... line. The voltage of the alternator neutral with respect to ground during the fault is 642.2 V

Description : A 3-phase 11 kV generator feeds power to a constant power unity power factor load of 100 MW through a 3-phase transmission line. The line-to line voltage at the terminals of the machine is maintained constant at 11 kV. The per ... 11 kV is  (A) 100 MVAR (B) 10.1 MVAR (C) -100 MVAR (D) -10.1 MVAR

Last Answer : A 3-phase 11 kV generator feeds power to a constant power unity power factor load of 100 MW through a 3-phase transmission line. The line-to line voltage at the terminals of the machine is maintained ... load to increase the line-to-line voltage at the load terminals to 11 kV is -10.1 MVAR

Description : Choose two appropriate auxiliary components of a HVDC transmission system from the following P. D.C line inductor Q. A.C line inductor R. Reactive power sources S. Distance relays on D.C line T. Series capacitance on A.C. line  (A) P and Q (B) P and R (C) Q and S (D) S and T

Last Answer : Choose two appropriate auxiliary components of a HVDC transmission system from the following P. D.C line inductor Q. A.C line inductor R. Reactive power sources S. Distance relays on D.C line T. Series capacitance on A.C. line  (A) P and Q (B) P and R (C) Q and S (D) S and T

Description : A hydraulic turbine having rated speed of 250 rpm is connected to a synchronous generator. In order to produce power at 50 Hz, the number of poles required in the generator are (A) 6 (B) 12 (C) 16 (D) 24

Last Answer : A hydraulic turbine having rated speed of 250 rpm is connected to a synchronous generator. In order to produce power at 50 Hz, the number of poles required in the generator are 24

Description : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume constant power input to the ... the time of fault will be  (A) 1.528 (B) 1.018 (C) 0.848 (D) 0.509

Last Answer : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume ... the shaft. The accelerating torque in the generator in MNm at the time of fault will be 1.018 

Description : A 800 kV transmission line is having per phase line inductance of 1.1 mH/km and per phase line capacitance of 11.68 nF/km. Ignoring the length of the line, its ideal power transfer capability in MW is (A) 1204 MW (B) 1504 MW (C) 2085 MW (D) 2606 MW

Last Answer : A 800 kV transmission line is having per phase line inductance of 1.1 mH/km and per phase line capacitance of 11.68 nF/km. Ignoring the length of the line, its ideal power transfer capability in MW is 2085 MW

Description : For harnessing low variable water heads, the suitable hydraulic turbine with high percentage of reaction and runner adjustable vanes is  (A) Kaplan (B) Francis (C) Pelton (D) Impeller

Last Answer : For harnessing low variable water heads, the suitable hydraulic turbine with high percentage of reaction and runner adjustable vanes is Kaplan 

Description : In the thermal power plants, the pressure in the working fluid cycle is developed by  (A) condenser (B) super heater (C) feed water pump (D) turbine

Last Answer : In the thermal power plants, the pressure in the working fluid cycle is developed by feed water pump 

Description : At an industrial sub-station with a 4 MW load, a capacitor of 2 MVAR is installed to maintain the load power factor at 0.97 lagging. If the capacitor goes out of service, the load power factor becomes (A) 0.85 (B) 1.00 (C) 0.80 lag (D) 0.90 lag

Last Answer : At an industrial sub-station with a 4 MW load, a capacitor of 2 MVAR is installed to maintain the load power factor at 0.97 lagging. If the capacitor goes out of service, the load power factor becomes  0.80 lag

Description : High Voltage DC (HVDC) transmission is mainly used for  (A) bulk power transmission over very long distances (C) inter-connecting two systems with same nominal frequency (C) eliminating reactive power requirement in the operation (D) minimizing harmonics at the converter stations

Last Answer : High Voltage DC (HVDC) transmission is mainly used for bulk power transmission over very long distances 

Description : An 800 kV transmission line has a maximum power transfer capacity of P. If it is operated at 400 kV with the series reactance unchanged, the new maximum power transfer capacity is approximately (A) P (B) 2P (C) P / 2 (D) P / 4

Last Answer : An 800 kV transmission line has a maximum power transfer capacity of P. If it is operated at 400 kV with the series reactance unchanged, the new maximum power transfer capacity is approximately P / 4

Description : The p.u. parameter for a 500 MVA machine on its own base are: inertia, M = 20 p.u. ; reactance, X = 2 p.u. The p.u. values of inertia and reactance on 100 MVA common base, respectively, are (A) 4, 0.4 (B) 100, 10 (C) 4, 10 (D) 100, 0.4

Last Answer : The p.u. parameter for a 500 MVA machine on its own base are: inertia, M = 20 p.u. ; reactance, X = 2 p.u. The p.u. values of inertia and reactance on 100 MVA common base, respectively, are 100, 0.4

Description : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/69 kV rating. A 0.72 ... load (in per unit) in generator will be (A) 36 (B) 1.44 (C) 0.72 (D) 0.18

Last Answer : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/ ... MVA and 69 kV in load circuit, the value of the load (in per unit) in generator will be 36 

Description : An HVDC link consist of rectifier, inverter transmission line and other equipments. Which one of the following is true for this link ?  (A) The transmission line produces/ supplies ... ) Both the converters (rectifier and inverter) consume reactive power from the respective connected AC systems

Last Answer : An HVDC link consist of rectifier, inverter transmission line and other equipments. Which one of the following is true for this link ?  (A) The transmission line produces/ supplies ... ) Both the converters (rectifier and inverter) consume reactive power from the respective connected AC systems

Description : A loss less transmission line having Surge Impedance Loading (SIL) of 2280 MW is provided with a uniformly distributed series capacitive compensation of 30%. Then, SIL of the compensated transmission line will be (A) 1835 MW (B) 2280 MW (C) 2725 MW (D) 3257 MW

Last Answer : A loss less transmission line having Surge Impedance Loading (SIL) of 2280 MW is provided with a uniformly distributed series capacitive compensation of 30%. Then, SIL of the compensated transmission line will be 2280 MW

Description : A three-phase, 33 kV oil circuit breaker is rated 1200 A, 2000 MVA, 3 s. The symmetrical breaking current is  (A) 1200 A (B) 3600 A (C) 35 kA (D) 104.8 kA

Last Answer : A three-phase, 33 kV oil circuit breaker is rated 1200 A, 2000 MVA, 3 s. The symmetrical breaking current is 35 kA 

Description : For enhancing the power transmission in along EHV transmission line, the most preferred method is to connect a  (A) Series inductive compensator in the line (B) Shunt inductive compensator at the ... (C) Series capacitive compensator in the line (D) Shunt capacitive compensator at the sending end

Last Answer : For enhancing the power transmission in along EHV transmission line, the most preferred method is to connect a Series capacitive compensator in the line

Description : A cylinder rotor generator delivers 0.5 pu power in the steady-state to an infinite bus through a transmission line of reactance 0.5 pu. The generator no-load voltage is 1.5 pu and the infinite bus voltage is 1 pu. The ... fault at the generator terminal is  (A) 53.5 (B) 60.2 (C) 70.8 (D) 79.6

Last Answer : A cylinder rotor generator delivers 0.5 pu power in the steady-state to an infinite bus through a transmission line of reactance 0.5 pu. The generator no-load voltage is 1.5 pu and the ... clearing angle, in degrees, for a three-phase dead short circuit fault at the generator terminal is 79.6

Description : If the reference bus is changed in two load flow runs with same system data and power obtained for reference bus taken as specified P and Q in the latter run, the system losses  A) Will be ... C) As well as complex bus voltage will changed D) As well as complex bus voltage will be unchanged

Last Answer : If the reference bus is changed in two load flow runs with same system data and power obtained for reference bus taken as specified P and Q in the latter run, the system losses Will be unchanged but complex bus voltages will change

Description : Which material is used in controlling chain reaction in a nuclear reactor?  A) Thorium B) Uranium C) Boron D)Beryllium

Last Answer : Which material is used in controlling chain reaction in a nuclear reactor?  A) Thorium B) Uranium C) Boron D)Beryllium

Description : The concept of an electrically short, medium and long line is primarily based on the  A) Nominal voltage of the line B) Physical length of the line C) Wave length of the line D) Power transmitted over the line

Last Answer : The concept of an electrically short, medium and long line is primarily based on the  Physical length of the line