The maximum thickness of expansion joint in rigid pavements is
(A) 0
(B) 25 mm
(C) 50 mm
(D) 100 mm

1 Answer

Answer :

Answer: Option B

Related questions

Description : The function of an expansion joint in rigid pavements is to (A) Relieve warping stresses (B) Relieve shrinkage stresses (C) Resist stresses due to expansion (D) Allow free expansion

Last Answer : Answer: Option D

Description : The nominal thickness of an expansion joint in brick walls, is kept more than (A) 5 mm (B) 10 mm (C) 15 mm (D) 20 mm

Last Answer : Answer: Option D

Description : The maximum spacing of contraction joints in rigid pavements is (A) 2.5 m (B) 3.5 m (C) 4.5 m (D) 5.5 m

Last Answer : Answer: Option C

Description : The thickness of bituminous carpet varies from (A) 20 to 25 mm (B) 50 to 75 mm (C) 75 to 100 mm (D) 100 to 120 mm

Last Answer : Answer: Option A

Description : To prevent compressive stresses in a rigid concrete pavement, the joint provided, is (A) Expansion joint (B) Contraction joint (C) Hinged joint (D) All the above

Last Answer : Answer: Option D

Description : Minimum thickness of load bearing RCC wall should be (A) 50 mm (B) 100 mm (C) 150 mm (D) 200 mm

Last Answer : (B) 100 mm

Description : Tie bars in cement concrete pavements are at (A) Expansion joints (B) Contraction joints (C) Warping joints (D) Longitudinal joints

Last Answer : Answer: Option D

Description : Plastic bitumen is generally used for (A) Road pavements (B) Expansion joints (C) Crack fillings (D) None to these

Last Answer : Answer: Option C

Description : If the width of a pavement slab is 7.5 m, thickness 20 cm and working stress 1400 kg/cm2 , spacing of 10 mm tie bars for the longitudinal joint, is (A) 10 cm (B) 20 cm (C) 30 cm (D) 40 cm

Last Answer : Answer: Option C

Description : Maximum heat dissipation occurs from a steel wire (k = 0.5 W/m. k) of 15 mm diameter exposed to air (h = 20W/m2.k), when the insulation thickness is __________ mm. (A) 15 (B) 25 (C) 10 (D) 30

Last Answer : (B) 25

Description : The maximum thickness of the metal which can be welded using ultrasonic welding is __________ mm. (A) 0.5 (B) 3 (C) 10 (D) 25

Last Answer : (B) 3

Description : The difference in the reservoir level and the lowest point of the water mains is 180 m. The  expected pressure due to water hammer is 7.5 kg/cm2  in a pressure conduit of diameter 1 m.  Assuming the efficiency of the ... , is  (A) 10 mm  (B) 15 mm  (C) 20 mm  (D) 25 mm 

Last Answer : (C) 20 mm

Description : For determining the ultimate bearing capacity of soil, the recommended size of a square bearing plate to be used in load plate test should be 30 to 75 cm square with a minimum thickness of (A) 5 mm (B) 10 mm (C) 15 mm (D) 25 mm

Last Answer : Answer: Option D

Description : The minimum thickness of the cover at the end of a reinforcing bar should not be less than twice the diameter of the bar subject to a minimum of (A) 10 mm (B) 15 mm (C) 20 mm (D) 25 mm

Last Answer : Answer: Option D

Description : In a cross joint tensile test the following observations were made: Specimen width 20mm, Material thickness 20mm, Max Load: 180kN, Break position: Parent Plate. What is the UTS? a) 45 kN/mm b) 450 N/mm2c) 39 kN/mm2d) 39 N/mm2

Last Answer : b) 450 N/mm2

Description : In reinforced concrete footing on soil, the minimum thickness at edge should not be less than (A) 100 mm (B) 150 mm (C) 200 mm (D) 250 mm

Last Answer : Answer: Option B

Description : The slump recommended for mass concrete is about (A) 25 mm to 50 mm (B) 50 mm to 100 mm (C) 100 mm to 125 mm (D) 125 mm to 150 mm

Last Answer : Answer: Option A

Description : The concrete slump recommended for beams and slabs; is (A) 25 to 50 mm (B) 25 to 75 mm (C) 30 to 125 mm (D) 50 to 100 mm

Last Answer : Answer: Option C

Description : The concrete slump recommended for columns, is (A) 25 to 50 mm (B) 25 to 75 mm (C) 75 to 125 mm (D) 50 to 100 mm

Last Answer : Answer: Option C

Description : The concrete slump recommended for foundations, is (A) 25 to 50 mm (B) 30 to 125 mm (C) 50 to 100 mm (D) 75 to 125 mm

Last Answer : Answer: Option C

Description : Steel pipe are  (A) Suitable for withstanding high internal pressure  (B) Connected by riveted or welded joints  (C) Generally laid underground and no expansion joint is required  (D) Likely to last 100 years under ordinary conditions 

Last Answer : (D) Likely to last 100 years under ordinary conditions 

Description : For two plates of equal thickness, full strength of square-edged fillet weld can be ensured if its maximum size is limited to (a) 1.5 mm less than the plate thickness (b) 67% of the plate thickness (c) 80% of the plate thickness (d) Thickness of the plate

Last Answer : (a) 1.5 mm less than the plate thickness

Description : The maximum of spacing of side face reinforcement shall not exceed [ A ] 300 mm [ B ] Web thickness [ C ] Lesser of (a) and (b) [ D ] Greater of (a) and (b)

Last Answer : [ C ] Lesser of (a) and (b)

Description : The maximum total settlement for raft foundation on clayey soils should be limited to (A) 25 mm (B) 25 to 40 mm (C) 40 to 65 mm (D) 65 to 100 mm

Last Answer : Answer: Option D

Description : The maximum total settlement for isolated foundations on clayey soils should be limited to (A) 25 mm (B) 40 mm (C) 65 mm (D) 100 mm

Last Answer : Option C

Description : Maximum daily traffic capacity of bituminous pavements is (A) 500 tonnes per day (B) 1000 tonnes per day (C) 1500 tonnes per day (D) 2000 tonnes per day

Last Answer : Answer: Option C

Description : Independent displacement components at each joint of a rigid-jointed plane frame are (A) Three linear movements (B) Two linear movements and one rotation (C) One linear movement and two rotations (D) Three rotations

Last Answer : (B) Two linear movements and one rotation

Description : The number of independent displacement components at each joint of a rigid-jointed space frame is (A) 1 (B) 2 (C) 3 (D) 6

Last Answer : (D) 6

Description : A loudspeaker cabinet has an internal volume of 5,184 in3 (84,950 cm3 ). It has a port area on the baffle of 50 in2 (322.58cm2 ) and a thickness of 0.70 in (18 mm). What is the Helmholtz resonance, in hertz, of this loudspeaker enclosure? A. 250 Hz B. 245 Hz C. 240 Hz D. 255 Hz

Last Answer : C. 240 Hz

Description : Vibrating screens have capacity in the range of __________ tons/ft 2 .mm mesh size. (A) 0.2 to 0.8 (B) 5 to 25 (C) 50 to 100 (D) 100 to 250

Last Answer : (A) 0.2 to 0.8

Description : A steel bar 5 m × 50 mm is loaded with 250,000 N. If the modulus of elasticity of the material is 0.2  MN/mm2  and Poisson's ratio is 0.25, the change in the volume of the bar is:  (A) 1.125 cm3 (B) 2.125 cm3 (C) 3.125 cm3 (D) 4.125 cm

Last Answer : (C) 3.125 cm

Description : If the viscosity of ground water is 1.00, the Slitcher's constant is 400, the effective size of soil particles in aquifer is 0.5 mm and hydraulic gradient is 1 in 80, the velocity of flow is (A) 0.25 m/day (B) 0.50 m/day (C) 1.00 m/day (D) 1.25 m/day

Last Answer : Answer: Option D

Description : Pick up the incorrect statement from the following: (A) While measuring a distance with a tape of length 100.005 m, the distance to be increasing by 0.005 m for each tape length (B) An increase in ... ) A 100 m tape of cross section 10 mm 0.25 mm stretches about 10 mm under 5 kg pull

Last Answer : (B) An increase in temperature causes a tape to increase in length and the measured distance is too large

Description : Thickness of Lining/Charge is kept? (i) 20 mm. (ii) 25 mm* (iii) 30 mm (iv) As decided by the site supervisor

Last Answer : (ii) 25 mm*

Description : As per IRCA rules, the rejection limits for wheel flange thickness is - (a) 38mm (b) 25.4mm (c) 16mm* (d) 20 mm

Last Answer : (c) 16mm*

Description : Find the shear stress in a flange at the junction of hub in rigid flanged coupling if torsional moment is 2980N-m and diameter of hub being 125mm. Also the thickness of flange is 25mm. a) 6.77N/mm2 b) 10.24N/mm2 c) 4.84N/mm2 d) 4.22N/mm2

Last Answer : c) 4.84N/mm2

Description : According to IS:456-2000, the maximum allowable crack width (in mm) for mild type of environmental condition [ A ] 0.1 [ B ] 0.2 [ C ] 0.25 [ D ] 0.3

Last Answer : [ D ] 0.3

Description : According to IS:456-2000, the maximum allowable crack width (in mm) for mild type of environmental condition [ A ] 0.1 [ B ] 0.2 [ C ] 0.25 [ D ] 0.3

Last Answer : [ D ] 0.3

Description : The maximum thickness of concrete floor of a cement warehouse, is (A) 10 cm (B) 15 cm (C) 20 cm (D) 25 cm

Last Answer : (D) 25 cm

Description : If d is the diameter of the pipe, p is the total internal pressure, f is the permissible tensile stress  and n is the effective of the joint, the thickness t of metal pipe, is  (A) n (pd/2f)  (B) (1/n) (pd/2f)  (C) (1/n) (pd/3f)  (D) (1/n) (pf/d

Last Answer : (B) (1/n) (pd/2f) 

Description : The maximum non-verticality of the bore of a well 200 m deep, may be permitted up to (A) 25 cm (B) 50 cm (C) 75 cm (D) 100 cm

Last Answer : (D) 100 cm

Description : The least thickness of class B cast iron (spun) pipe, is (A) 7.2 mm (B) 7.9 mm (C) 8.6 mm (D) 10 mm

Last Answer : (C) 8.6 mm

Description : The aggregates required for one kilometre length of water bound macadam road per meter width and for 10 mm thickness is (A) 8 cubic meter (B) 10 cubic meter (C) 12 cubic meter (D) 15 cubic meter

Last Answer : Answer: Option C

Description : The stretcher bond in brick masonry can be used only when the thickness of wall is (A) 90 mm (B) 180 mm (C) 190 mm (D) 280 mm

Last Answer : Answer: Option A

Description : The nominal thickness of one brick wall in mm, is (A) 90 mm (B) 150 mm (C) 190 mm (D) 200 mm

Last Answer : Answer: Option D

Description : The type of ashlar masonry in which stones are finely chisel dressed and thickness of joints does not exceed 3 mm, is (A) Chamfered ashlar masonry (B) Ashlar facing masonry (C) Random coursed ashlar masonry (D) Coursed ashlar masonry

Last Answer : Answer: Option D

Description : While placing of concrete the thickness of each layer for R.C.C. is [ A ] 150 to 300 mm [ B ] 450 mm [ C ] 500 to 750 mm [ D ] 500 mm

Last Answer : [ A ] 150 to 300 mm

Description : The minimum cover to the ties or spirals should not be less than (A) 15 mm (B) 20 mm (C) 25 mm (D) 50 mm

Last Answer : Answer: Option C

Description : In slump test, each layer of concrete is compacted by a steel rod 60 cm long and of 16 mm diameter for (A) 20 times (B) 25 times (C) 30 times (D) 50 time

Last Answer : Answer: Option B