Which of the following units is not present in both the vapor
compression refrigeration system and absorption refrigeration system? (A) Expansion valve
(B) Condenser
(C) Refrigerator
(D) Compressor

1 Answer

Answer :

(D) Compressor

Related questions

Description : In vapour compression refrigeration system, refrigerant occurs as liquid between (a) condenser and expansion valve (b) compressor and evaporator (c) expansion valve and evaporator (d) compressor and condenser

Last Answer : Ans: c

Description : In a refrigeration cycle, the flow of refrigerant is controlled by (a) compressor (b) condenser (c) evaporator (d) expansion valve

Last Answer : Ans: d

Description : Where does the lowest temperature occur in a vapour compression cycle ? (a) condenser (b) evaporator (c) compressor (d) expansion valve

Last Answer : Ans: b

Description : The higher temperature in vapour compression cycle occurs at (a) compressor discharge. (b) expansion valve (c) evaporator (d) condenser discharge

Last Answer : Ans: a

Description : In vapour compression cycle the condition off refrigerant is dry saturated vapour (a) after passing through the condenser (b) before passing through the condenser (c)before entering the expansion valve (d) before entering the compressor

Last Answer : Ans: D

Description : Out of the following refrigeration cycles, which one has maximum COP? (A) Air cycle (B) Carnot cycle (C) Ordinary vapor compression cycle (D) Vapor compression with a reversible expansion engin

Last Answer : (B) Carnot cycle

Description : Presence of moisture in a refrigerant affects the working of (a) compressor (b) condenser (c) evaparator (d) expansion valve.

Last Answer : Ans: a

Description : Most of the domestic refrigerators work on the following refrigeration system (a) vapour compression (b) vapour absorption (c) carnot cycle (d) electrolux refrigerator

Last Answer : Ans: a

Description : In vapour compression cycle the condition of refrigerant is superheated vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) beforeentering the expansion valve

Last Answer : Ans: b

Description : In vapour compression cycle, the condition of refrigerant is high pressure saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve

Last Answer : Ans: d

Description : In vapour compression cycle, the condition of refrigerant is very wet vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve

Last Answer : Ans: c

Description : In vapour compression cycle, the condition of refrigerant is saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion throttle valve (d) before entering the expansion valve

Last Answer : Ans: a

Description : Domestic refrigerator working on vapour compression cycle uses the following type of expansion device (a) electrically operated throttling valve (b) manually operated valve (c) thermostatic valve (d) capillary tube

Last Answer : Ans: d

Description : Lowering of condenser temperature (keeping the evaporator temperature constant) in case of vapour compression refrigeration system results in (A) Increased COP (B) Same COP (C) Decreased COP (D) Increased or decreased COP; depending upon the type of refrigerant

Last Answer : (A) Increased COP

Description : The effect of changing the evaporator temperature on COP as compared to that of changing the condenser temperature (in vapour compression refrigeration system) is (A) Less pronounced (B) More pronounced (C) Equal (D) Data insufficient, can't be predicted

Last Answer : (B) More pronounced

Description : In vapour compression refrigeration system, if the evaporator temperature and the condenser temperatures are -13°C and 37°C respectively, the Carnot COP will be (A) 5.2 (B) 6.2 (C) 0.168 (D) Data insufficient, can't be found out

Last Answer : A) 5.2

Description : Which of the following is an undesirable characteristic of a refrigerant? (A) It should be non-explosive (B) It should have a sub-atmospheric vapor pressure at the temperature in refrigerator coils (C) Its vapor pressure at the condenser temperature should be very high (D) None of these

Last Answer : (B) It should have a sub-atmospheric vapor pressure at the temperature in refrigerator coils

Description : Which of the following is a widely used refrigerant in vapour compression refrigeration system (using large centrifugal compressor)? (A) Freon (B) Liquid sulphur dioxide (C) Methyl chloride (D) Ammonia

Last Answer : (A) Freon

Description : In a flooded evaporator refrigerator, an accumulator at suction of compressor is used to (a) collect liquid refrigerant and prevent it from going to compressor (b) detect liquid in vapour (c) superheat the vapour (d) increase refrigeration effect

Last Answer : Ans: a

Description : Domestic refrigerator usually works on the __________ refrigeration cycle. (A) Carnot (B) Air (C) Absorption (D) vapour-ejection

Last Answer : (C) Absorption

Description : Pick out the wrong statement. (A) A refrigeration cycle violates the second law of thermodynamics (B) Refrigeration cycle is normally represented by a temperature vs. entropy plot (C) In a refrigerator, ... (D) One ton of refrigeration is equivalent to the rate of heat absorption equal to 3.53 kW

Last Answer : (A) A refrigeration cycle violates the second law of thermodynamics

Description : Which of the following has the minimum value of COP for a given refrigeration effect? (A) Reverse Carnot cycle (B) Ordinary vapour-compression cycle (C) Vapour-compression process with a reversible expansion engine (D) Air refrigeration cycle

Last Answer : (D) Air refrigeration cycle

Description : Out of the following refrigeration cycles, which one has the minimum COP (Co-efficient of performance)? (A) Air cycle (B) Carnot cycle (C) Ordinary vapour compression cycle (D) Vapour compression with a reversible expansion engine

Last Answer : A) Air cycle

Description : Aqua ammonia is used as refrigerant in the following type of refrigeration system (a) compression (b) direct (c) indirect (d) absorption

Last Answer : Ans: d

Description : Which of the following processes cannot be made reversible even under ideal condition of operation? (A) Free expansion of a gas (B) Compression of air in a compressor (C) Expansion of steam in a turbine (D) All (A), (B) & (C)

Last Answer : (A) Free expansion of a gas

Description : Ammonia-absorption refrigeration cycle requires (a) very little work input (b) maximum work input (c) nearly same work input as for vapour compression cycle (d) zero work input

Last Answer : Ans: a

Description : One of the purposes of sub-cooling the liquid refrigerant is to (a) reduce compressor overheating (b) reduce compressor discharge temperature (c) increase cooling effect (d) ensure that only liquid and not the vapour enters the expansion (throttling) valve

Last Answer : Ans: d

Description : The condition of refrigerant before entering the expansion or throttle valve, in a vapour compression system (a) dry vapour (b) wet vapour (c)liquid-vapour mixture (d) high pressure saturated liquid

Last Answer : Ans: d

Description : In a vapour compression cycle, the refrigerant immediately after expansion valve is (a) liquid (b) sub-cooled liquid (c) saturated liquid (d) wet vapour

Last Answer : Ans: d

Description : Suggest the type of heat exchangers for following applications - (i) Dairy plant (Milk Chilling Plant) (ii) Condenser of refrigeration system. (House hold system) Justify your answers.

Last Answer : Types of Heat Exchanger Used for 1) Dairy Plant (Milk Chilling Plant)- Plate Type Heat Exchanger Because , It is made up of aluminum alloy which provides higher rate of heat ... In tubes generally turbulent flow is develop which reduces scale deposition. Less installation and maintenance cost.

Description : An ideal liquid refrigerant should (A) Not have a sub-atmospheric vapour pressure at the temperature in the refrigerator coils (B) Not have unduly high vapour pressure at the condenser temperature (C) Both (A) and (B) (D) Have low specific heat

Last Answer : (C) Both (A) and (B)

Description : The change in evaporator temperature in a refrigeration cycle, as compared to change in condenser temperature, influences the value of C.O.P. (a) more (b) less (c) equally. (d) unpredictable

Last Answer : Ans: a

Description : The C.O.P. of a refrigeration cycle with lowering of condenser temperature, keeping the evaporator temperatureconstant, will (a) increase (b) decrease (c) may increase or decrease depending on the type of refrigerant used (d) remain unaffected

Last Answer : Ans: a

Description : The C.O.P of a refrigeration cycle with increase in evaporator temperature, keeping condenser temperature constant, will (a) increase (b) decrease (c) remain unaffected (d) may increase or decrease depending on the type of refrigerant used

Last Answer : Ans: a

Description : A refrigeration cycle operates between condenser temperature of + 27°C and evaporator temperature of- 23°C. TheCarnot coefficient of performance of cycle will be (a) 0.2 (b) 1.2 (c) 5 (d) 6

Last Answer : Ans: c

Description : Pick out the wrong statement. (A) The condensing film co-efficient is about 3 times lower for vertical condenser as compared to the equivalent horizontal condenser for identical situation ( ... in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Last Answer : (D) Overall heat transfer co-efficient in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Description : COP of a refrigerator drawing 1 kW of power per ton of refrigeration is about (A) 0.5 (B) 3.5 (C) 4.5 (D) 8.5

Last Answer : (B) 3.5

Description : Refrigeration capacity of a household refrigerator may be round about __________ tons. (A) 0.15 (B) 1.5 (C) 4.5 (D) 6.5

Last Answer : (A) 0.15

Description : Co-efficient of Performance (COP) of a refrigerator is the ratio of the (A) Work required to refrigeration obtained (B) Refrigeration obtained to the work required (C) Lower to higher temperature (D) Higher to lower temperature

Last Answer : (B) Refrigeration obtained to the work required

Description : A domestic refrigerator has a/an __________ cooled condenser. (A) Water (B) Air (C) Evaporative (D) Gas

Last Answer : (B) Air

Description : Reducing suction pressure in refrigeration cycle (a) lowers evaporation temperature (b) increases power required per ton of refrigeration (c) lowers compressor capacity because vapour is lighter (d) all of the above.

Last Answer : Ans: d

Description : What Is The Use Of Compressor In Refrigeration?

Last Answer : The compressor does exactly as its name says: it compresses the refrigerant. The compressor receives low pressure gas from the evaporator and converts it to high pressure gas. As mentioned earlier, as the gas is compressed, the temperature rises. The hot refrigerant gas then flows to the condenser.

Description : Why Is A Compressor Used In Refrigeration?

Last Answer : The compressor does exactly as its name says: it compresses the refrigerant. The compressor receives low pressure gas from the evaporator and converts it to high pressure gas. As mentioned earlier, as the gas is compressed, the temperature rises. The hot refrigerant gas then flows to the condenser.

Description : In refrigerator, liquid receiver is required between condenser and flow controlling device, if quantity of refrigerant for system is (a) less than 2 kg (b) more than or equal to 3.65 kg (c) more than 10 kg (d) there is no such consideration

Last Answer : Ans: b

Description : The separation of liquid droplets from the vapor is done by a/an __________, in the evaporators. (A) Steam ejector (B) Entrainment separator (C) Compressor (D) Vacuum pump

Last Answer : (B) Entrainment separator

Description : Moisture in freon refrigeration system causes (a) ineffective refrigeration (b) high power consumption (c) freezing automatic regulating valve (d) corrosion of whole system

Last Answer : Ans: c

Description : In the illustration if the compressor fails to start but the condenser fan motor is running the problem is _______. EL-0042 A. no power between L1 and L2 B. the yellow wire is open at the freezer temperature control switch C. the overload is open D. the blue wire from the defrost heater is open

Last Answer : Answer: C

Description : In the illustration if the compressor fails to start but the condenser fan motor is running the problem is _______. EL-0043 A. no power between L1 and L2 B. the yellow wire is open at the freezer temperature control switch C. the overload is open D. the blue wire from the defrost heater is open

Last Answer : Answer: C

Description : Power saving guide label is stickled on_______ A. Internal parts of AC C. On condenser and compressor B. External cover of AC D. On back cover of AC

Last Answer : External cover of AC

Description : Pick out the wrong statement about cavitation. (A) Sudden reduction of pressure in a fluid flow system caused by flow separation, vortex formation or abrupt closing of valve leads to cavitation ... (D) Large scale cavitation cannot damage pipeline, restrict fluid flow and damage steam turbine blades

Last Answer : (D) Large scale cavitation cannot damage pipeline, restrict fluid flow and damage steam turbine blades