The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

1 Answer

Answer :

The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Related questions

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Last Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Last Answer : In a single phase motor the centrifugal switch disconnects auxiliary winding of the motor.

Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : State suitable single phase motor for following applications: (i) Table fan (ii) Mixers and Grinders

Last Answer : Application Suitable Single Phase Motor Table Fan 1) Capacitor split phase motor 2) Capacitor start capacitor run motor Mixers and Grinders 1) Universal motor 2) A.C. Series motor

Description : Why is a capacitor used in a single phase motor and not in three phase motor ?

Last Answer : In 1-phase induction motor capacitor work is generate the auxiliary winding current than excite the main winding to rotor starts rotate. After rotor start rotating about 75% of their speed than auxiliary ... emf to start the motor.so,in 3-phase induction motor is self start induction motor.

Description : working principle of single phase motor

Last Answer : The Stator of single phase induction motor houses two windings  1. Main (Running) winding 2. Auxiliary (Starting ) winding Rotor of single phase induction motor is ... with starting winding or a capacitor may be permanently connected in series with Auxiliary (Starting ) winding.

Description : Explain the working of a single phase capacitor start induction motor. 

Last Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

Description : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Last Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Last Answer : If a single phase induction motor runs slower than normal, the most likely defect is worn bearings.

Description : An unexcited single phase synchronous motor is ?

Last Answer : An unexcited single-phase synchronous motor is reluctance motor.

Description : How does a single phase induction motor work?

Last Answer : As we know that single phase induction is not self started because for self started we require atleast two revolving field but single phase induction motor has only one. So we provide extra ... 1phase IM classified as split phase IM, capacitor start capacitor run, capacitor start induction run.

Description : explain the working of single phase induction motor.

Last Answer : Stator has two winding namely main winding and auxiliary winding.when single phase ac supply is given to the motor,its produces alternating field.this field cut by a cage rotor.so some emf ... due to this emf,rotor flux produced.the interaction between two fluxes produce torque.so rotor rotates.

Description : Single Phase Induction Motor

Last Answer : Single Phase Induction Motor Single phase induction motor is mostly used in home, office, shop and many single phase appliances like pumps,  ... torque and silent operation. It is uses where silent operation is required.

Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Last Answer : The starting winding of a single-phase motor is placed in stator.

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Last Answer :  Sandwich type winding is used in 3 phase shell-type transformer.

Last Answer : Direction of rotation of a split phase motor can be reversed by reversing the connection of either running winding or starting winding.

Last Answer : In a split phase motor the starting winding is connected through a centrifugal switch.

Last Answer : In a two value capacitor motor, the capacitor used for running purposes is paper spaced oil filled type.

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : The damping winding in synchronous motor is generally used to?

Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

Description : In synchronous motor, does the winding losses vary with load?

Last Answer : No, in the synchronous motor the winding losses do not vary with load.

Last Answer : The operating voltage of a meggar is about 100 V.

Last Answer : In a meggar controlling torque is provided by coil.

Last Answer : The electrical power to a meggar is provided by permanent magnet D.C. generator.

Description : SINGLE PHASE INDUCTION MOTORS MCQ

Last Answer : 101. After the starting winding of a single phase induction motor is disconnected from supply, it continues to run only on (a) running winding (b) rotor winding (c) field winding (d) compensating winding Ans: a ... motor is usually reduced by using (a) gearing (b) belts (c) brakes (d) chains Ans: a

Description : Draw single phase full wave mid-point converter for inductive load. Draw input and output waveforms for it. 

Last Answer : Circuit Diagram: Waveforms:

Description : Single phase transformer

Last Answer : Single phase Transformer Transformer

Description : Explain MCB and ELCB with connection diagram supplying single phase load. 

Last Answer : OR OR Explanation: * MCB provides short circuit protection. * MCB provides overload protection * ELCB provides earth fault protection. * MCB is in series with ... occurs, the ELCB cuts off the power within the time of 0.1 sec. automatically to protect the personnel. 

Description : Explain construction and working principle of single phase transformer.

Last Answer : A single phase transformers is an electrical device that accepts single-phase AC power and outputs single-phase AC. PRINCIPLE... The single-phase transformer works on the principle of ... and secondary windings. Thin steel laminations shall be employed to prevent power losses from the core.

Description : Give the operation of single phase full wave bridge controlled converter with RL load with a neat diagram. Also draw its waveform.

Last Answer : Single phase fully control bridge converter with RL load: 1. During positive half cycle of input voltage, T1 and T2 are forward biased and during negative half cycle, T3 and T4 are forward biased. Therefore, T1-T2 ... cycle till the firing of next pair of SCRs as shown in the waveform.

Description : State advantages of three phase over single phase.

Last Answer : Advantages of 3-phase system over 1-phase system: -  1. More output: For the same size, output of poly-phase machines is always higher than single phase machines.  2. Smaller size: For ... are self- starting: The three phase ac motors are self starting, while single phase induction motor are not.

Description : A single phase transformer has resistance and reactance of 0.2 pu and 0.6 pu respectively. Its pu voltage regulation at 0.8 pf lagging would he

Last Answer : A single phase transformer has resistance and reactance of 0.2 pu and 0.6 pu respectively. Its pu voltage regulation at 0.8 pf lagging would he 0.52

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is (A) 28.2 mm (B) 26.4 mm (C) 24.4 mm (D) 22.0 mm

Last Answer : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is 22.0 mm

Description : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

Last Answer : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is 500 W

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Last Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%