Please Log in or Register for more.

During open circuit test of a transformer?

110 views

1 Answer

Answer :

During open circuit test of a transformer primary is supplied rated voltage.

Like 0 like

Please log in or register to answer this question.

Related Questions


116 views 1 answer








Last Answer : Primary side is low voltage side and secondary side is high voltage side.

Show More

123 views 1 answer







Explain the open delta (delta-delta) test on transformer.

Show More

75 views 0 answers














Last Answer : Low voltage side is short circuited.

Show More

164 views 1 answer








Last Answer : Primary is high voltage side and Secondary is low Voltage side.

Show More

123 views 1 answer








Last Answer : In short circuit test of transformer the low voltage side is short circuited . On high voltage side the voltmeter is connected in parallel and ammeter in series and also a wattmeter is ... circuit test is done for determining impedance and losses. In this test iron losses is neglected.

Show More

171 views 1 answer







An open-circuit test on a transformer is conducted primarily to measure?
Last Answer : The open-circuit test in a transformer is used to measure

Show More

625 views 2 answers








Last Answer : Short circuit test on transformers is conducted to determine copper losses.

Show More

218 views 1 answer







A no-load test is performed on a transformer to determine?
Last Answer : A no-load test is performed on a transformer to determine magnetizing current and loss.

Show More

124 views 1 answer







Sumpner's test is conducted on transformer to determine?
Last Answer : Sumpner's test is conducted on transformer to determine temprature.

Show More

122 views 1 answer







Describe the difference between an open circuit and a short circuit.
Last Answer : Open circuit means the wire is cut meaning power will not flow and close circuit means wire is not cut and hence power will flow.Short circuit is the same as close circuit

Show More

7.8k views 3 answers







A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is (A) 300 W (B) 150 W (C) 45 W (D) 20 W
Last Answer : A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is 150 W

Show More

293 views 1 answer








Last Answer : It is required to measure the true open circuit e.m.f. of a battery. The best device is D.C. potentiometer.

Show More

284 views 1 answer







Explain open emitter BJT drive circuit.
Last Answer : open emitter BJT drive circuit:

Show More

262 views 1 answer







Equivalent circuit of transformer
Last Answer : Equivalent Circuit Diagram of Transformer Referred to Primary: V1 -Primary Input voltage I1 - Input Current I0- Exciting current/ No load current Im- Magnetizing component ... equivalent of secondary terminal voltage ZL- Load impedance ZL ′- Primary equivalent of load impedance

Show More

381 views 2 answers







Polarity Test of Transformer
Last Answer : Polarity Test of Transformer

Show More

309 views 1 answer







If a 5-bus test system contains 6 transmission lines and one transformer, how many non-zero elements are there in the system Y-bus ? (A) 25 (B) 12 (C) 11 (D) 19
Last Answer : If a 5-bus test system contains 6 transmission lines and one transformer, 19 non-zero elements are there in the system Y-bus.

Show More

3.0k views 1 answer







 An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 
Last Answer :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Show More

260 views 1 answer








Last Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Show More

174 views 1 answer







Why phasing out and polarity test is carried out on three phase transformer?
Last Answer : The phasing out test is carried out to identify the windings (primary and secondary) of corresponding phase of the three phase transformer. The polarity test is carried out to identify the ... identical polarity of the primary and secondary windings of each phase of the three phase transformer.

Show More

428 views 1 answer







When secondary of a current transformer is open-circuited its iron core will be?
Last Answer : When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

Show More

165 views 1 answer








Last Answer : Noise level test in a transformer is a type test.

Show More

102 views 1 answer







During short circuit test iron losses are negligible because?
Last Answer : During short circuit test iron losses are negligible because the voltage applied on primary side is low.

Show More

120 views 1 answer







How to Open a Tight Jar Lid
Last Answer : How to Open a Tight Jar Lid There are instances when you buy a stubborn jar of pickles (Learn how to pickle), peanut butter or mayonnaise that you can't open with your hands. It can drive you ... no time. If you enjoy reading this article, you might as well read how to can fruits and vegetables.

Show More

4 views 1 answer







How to Open a Can without a Can Opener
Last Answer : How to Open a Can without a Can Opener You're dying to sink your teeth into those canned peaches, but you find yourself without any can opener. At times like this, many people would easily give up ... you'll soon find yourself enjoying the yummy contents of the can. Be careful not to spill the food!

Show More

4 views 1 answer







Open-Face Shrimp Melt
Last Answer : Open-Face Shrimp Melt - serves 2 Preparation - 15 minutes 3 ounces shelled and deveined cooked small shrimp, cut lengthwise into halves 1/4 cup chopped celery 2 tbsp chopped scallion (green ... baking sheet arrange sandwiches and broil 6 inches from heat source until cheese melts, about 1 minute.

Show More

4 views 1 answer







What are the disadvantages of Open loop control system?
Last Answer : Open loop control system are less reliable. In open loop control system Optimization is not possible. Open loop control system are less accurate.

Show More

111 views 1 answer







Why CT is never operated with an open secondary ?
Last Answer : CT secondary should never be kept open because it will cause saturation of the core to a high level and very high voltage will appear across the secondary which can breakdown the insulation. One terminal of PT secondary is always grounded to avoid capacitive induction and for human safety

Show More

92 views 2 answers







What will happen to the gain margin if the gain of the open loop system is doubled? A) Doubled B) Becomes half C) Is not affected D) Becomes one-fourth 
Last Answer : What will happen to the gain margin if the gain of the open loop system is doubled? A) Doubled B) Becomes half C) Is not affected D) Becomes one-fourth 

Show More

199 views 1 answer







If the gain of the open loop system is doubled, the gain margin  (1) Is not affected (2) Gets doubled (3) Becomes half (4) Becomes one -forth
Last Answer : If the gain of the open loop system is doubled, the gain margin Becomes half

Show More

718 views 1 answer







An open resistor, when checked with an ohm-meter reads?
Last Answer : An open resistor, when checked with an ohm-meter reads infinite.

Show More

117 views 1 answer








Last Answer : Open circuited armature coil of a D.C. machine is identified by the scarring of the commutator segment to which open circuited coil is connected and indicated by a spark completely around the commutator.

Show More

160 views 1 answer








Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Show More

258 views 1 answer







What is an example of an open loop system?
Last Answer : Open loop system. Ex. Electric heater, washing machine, fan, electric switch, etc

Show More

100 views 1 answer







What are the advantages of open loop control system?
Last Answer : Open loop control system are simple to design. Open loop control system are generally stable.

Show More

124 views 1 answer







what is open loop and close loop control system?
Last Answer : A) In open loop system the input is independent         of output but output is depends on input. A-1. no feedback path in open loop s/m    -2. less accuracy than close loop s/m. Ex. Washing ...    -3. high accuracy. Ex. Air conditioner ( AC ), rocket launcher, radar          system, etc

Show More

129 views 2 answers







The changes in the volume of transformer cooling oil due to the variation of atmospheric temperature during day and night is taken care of by which part of the transformer?
Last Answer : The changes in the volume of transformer cooling oil due to the variation of atmospheric temperature during day and night is taken care of by conservator.

Show More

75 views 1 answer







Why the open circuit test on a transformer is conducted at rated voltage?
Last Answer : A:The open circuit on a transformer is conducted at a rated voltage because core loss depends upon the voltage. This open circuit test gives only core loss or iron loss of the transformer.

Show More

4 views 1 answer







49 The open circuit test is carried out in a transformer to find the A. Cu loss B. Core loss C. Total loss D. Insulation resistance
Last Answer : B. Core loss

Show More

10 views 1 answer







With the help of neat diagram, describe the procedure to carry out phasing out test on a 3 phase transformer. Also state the purpose of conducting this test on 3 phase transformer.
Last Answer : i) This test is carried out on 3-ph transformer to identify primary & secondary winding belonging to the same phase. ii) As shown in fig above all primary & secondary phases ... of this test is to check the respective phases of primary & secondary windings in 3-ph transformer

Show More

306 views 1 answer







Explain the effect of Harmonics on the Transformer.
Last Answer : Effect of Harmonics on the Transformer:  1. Core loss: Harmonic voltage increases the hysteresis and eddy current losses in the lamination. The amount of the core loss depends on ... small core vibrations.  5. Saturation problem: Sometimes additional harmonic voltage causes core saturation.

Show More

130 views 1 answer







List two special feature of welding transformer.
Last Answer : Special features of welding transformer: i) It is a step down transformer that reduces the source voltage to a voltage desired according to the demands of the welding process. ii) Having large primary turns and less ... V ii) Secondary voltage - 40 to 60 V iii) Secondary current - 200 to 600 A

Show More

153 views 1 answer







State two applications of isolation transformer
Last Answer : Applications of isolation transformer: i) Isolates the load equipment from supply ground: ii) Reduction of voltage spikes iii) It acts as a decoupling device. iv) Protects loads from harmonic distortion.

Show More

54 views 1 answer







State why a transformer always have an efficiency of more than 90%.
Last Answer : As transformer is static device with no moving parts, the losses due to friction & windage are completely absent. Hence transformer has efficiency of more than 90%.

Show More

279 views 1 answer







Single phase transformer
Last Answer : Single phase Transformer Transformer

Show More

261 views 1 answer







What is the use of transformer?
Last Answer : The use of transformer  is to do lower or raise  the voltage or currents in an electrical  circuit.  That's quite so simple. 

Show More

160 views 1 answer







Write about transformer on DC.
Last Answer : Transformer on DC : Transformer cannot work on DC. Transformer works on electromagnetic induction principle. Electromagnetic induction principle means when flux linking with coil changes and EMF induced in it ... winding insulation will burn. https://youtu.be/TVp_0fIfxqY

Show More

248 views 1 answer













State and justify which of the following two transformers is better:  Transformer A = 4% voltage regulation  Transformer B = 6% voltage regulation
Last Answer : Transformer A with 4% voltage regulation is better.  Justification: Voltage regulation refers to the percentage change in secondary voltage when load is changed from no-load to full-load with primary voltage ... 4% voltage regulation, which is less as compared to 6% of transformer B, it is better.

Show More

181 views 1 answer






Show More⇦ PreviousNext ⇨