Which of the following plants will take least time in starting from cold conditions to full-load operation? A) Nuclear power plant B) Steam power plant C) Hydro-electric power plant D) Gas turbine plant

2 Answers

Answer :

Which of the following plants will take least time in starting from cold conditions to full-load operation? A) Nuclear power plant B) Steam power plant C) Hydro-electric power plant D) Gas turbine plant

How i thought it was supposed to be nuclear...

Answer :

Hydro -electric power plant

Related questions

Description : Classify the hydro-electric plants according to the head and load basis.  

Last Answer : Classification the hydro-electric plants According to availability of Head of Water:  1. Very high head power plant 2. High head power plant 3. Medium head power plant 4. Low head power plant  ... -electric plants According to Load basis:   1. Base load power plant 2. Peak load power plant

Last Answer : Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.

Description : A circuit breaker for a 300 KW alternator is rated at 470 amperes of full continuous load. The amount of overcurrent allowed is 125%. Which of the following conditions will trip the breaker? A. ... 10 minutes. C. Momentary starting load of 550 amperes. D. Sustained current flow of 590 amperes.

Last Answer : Answer: D

Last Answer : The ratio of starting torque to full-load torque is least in case of shunt motors.

Last Answer : Generating capacity connected to the bus bars and ready to take load when switched on is known as spinning reserve.

Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed

Last Answer : Answer: B

Description : A distillation column with N plates is being operated under normal conditions. At some point of time, the operation is shifted to total reflux condition (i.e., no product and residue are ... and without total reflux (D) The top and bottom compositions correspond to the maximum enrichment available

Last Answer : (D) The top and bottom compositions correspond to the maximum enrichment available

Last Answer : In fossil fuel transportation cost is least.

Description : The purpose of 'R6' in the winch circuit shown in the illustration is to _______________. EL-0102 A. maintain dry conditions within the winch brake box B. keep the series field current at ... to assist the winch in stopping D. limit the armature current during lowering operation with heavy loads

Last Answer : Answer: C

Description : Compare base load plant with peak load plant. 

Last Answer : Sr.No. Points Base load plant Peak load plant  1 Definition The power plant which supplies base load of load curve is known as base load plant The power ... power station   Small capacity storage hydro, pumped storage hydro, gas, diesel power station. 

Last Answer : 1. Connected Load: It is the sum of load of all equipment's connected to supply system which are in use or not in use of each consumer. OR   The sum of connected load of all consumers ... is the maximum load which a consumer uses at a particular time period out of his total connected load. 

Description : A generating station has a maximum demand of 500 MW. The annual load factor is 50 percent. The energy generated per annum will be: A) 2.19 x 106 MWhr B) 600 MWhr C) 250 MWhr D) 7.50 x 106 MWhr

Last Answer : A generating station has a maximum demand of 500 MW. The annual load factor is 50 percent. The energy generated per annum will be: 2.19 x 106 MWhr 

Description : In order to have a lower cost of electrical energy generation the load factor  (1) and the diversity factor should be low (2) should be low but the diversity factor should be high (3) should be high but the diversity factor should be low (4) and the diversity factor both should be high

Last Answer : In order to have a lower cost of electrical energy generation the load factor and the diversity factor both should be high

Last Answer : Nuclear power plant is invariably used as base load plant.

Last Answer : In a load curve the highest point represents peak demand.

Last Answer : The increased load during summer months is due to increased use of fans and air conditioners.

Last Answer : Load curve is useful in deciding the operating schedule of generating units, sizes of generating units, total installed capacity of the plant.

Last Answer : The area under a load curve gives energy consumed.

Last Answer : Peak load plant can never have 100 percent load factor.

Last Answer : In two part tariff, variation in load factor will affect operating or running charges.

Last Answer : A load curve indicates average kWh (kW) energy consumption during the period.

Last Answer : High load factor indicates total plant capacity is utilised for most of the time.

Last Answer : The load factor of domestic load is usually 10 to 15%.

Last Answer : Load factor of a power station is generally less than unity.

Last Answer : Load factor of a power station is defined as average load/maximum demand.

Description : With a neat diagram explain medium head hydro-electric power plants. 

Last Answer : Diagram of medium head hydro-electric power plants:  Explanation:- If head of water is between 30 and 100 m, the plant is called a medium-head plant. Potential energy of ... Francis turbines are normally used. Alternator required in these plants is of low speed and large in diameter. 

Description : Large size steam plants and nuclear plants are suitable for   (a) Intermediate loads (b) Base loads (c) Both base and peak loads (d) Peak loads 

Last Answer : Large size steam plants and nuclear plants are suitable for Base loads

Description : The problematic pollutants in emission of coal based generating plants __________.  (A) SO₂ (B) NOx (C) CO (D) All of the above

Last Answer : The problematic pollutants in emission of coal based generating plants __________.  (A) SO₂ (B) NOx (C) CO (D) All of the above

Description : In hydroelectric power plants  (1) both operating and initial cost are high (2) both operating and initial cost are low (3) operating cost is low and initial cost is high (4) operating cost is high and initial cost is low

Last Answer : In hydroelectric power plants operating cost is low and initial cost is high

Last Answer : Most efficient plants are normally used as base load plants.

Description : The standard procedure for maintaining the charge in an emergency diesel starting battery is to trickle charge the battery _____________. A. continuously B. at least once each week C. whenever the charge falls to 75% of full charge D. whenever the electrolyte specific gravity falls to 1.250 or lower

Last Answer : Answer: A

Description : Echo suppressor is detrimental to full duplex operation because (A) It disables one of the two pairs in a four-wire trunk line when a signal is detected on the other pair. (B) It enables one of the ... It activates both the pairs of a four-wire trunk line. (D) It is independent of line conditions.

Last Answer : (A) It disables one of the two pairs in a four-wire trunk line when a signal is detected on the other pair.

Description : In a 15 HP induction-type motor with a cage rotor, the current required at standstill to produce starting torque is approximately ____________. A. half the full load current B. equal to the full load current C. five times the full load current D. ten to twenty times the full load current

Last Answer : Answer: C

Description : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be  A) 40 Nm B) 60 Nm C) 90 Nm D) 120 Nm

Last Answer : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be 40 Nm

Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Description : Which of the following problems will most likely occur if the starting winding of a split-phase induction motor failed to cutout once the motor was in continuous operation? A. The motor will overspeed. B. The ... reduced speed. C. A time delay will stop the motor. D. The winding will burn out.

Last Answer : Answer: D

Description : Erosion and pits formation on the impeller of a centrifugal pump may be due to (A) Cavitation (B) Low speed of impeller (C) Its operation with delivery valve closed for considerable time after starting the pump (D) Off centering of pump with motor

Last Answer : (A) Cavitation

Description : n an NC machining operation, the tool has to be moved from point (5, 4) to point (7, 2) alonga circular path with centre at (5, 2). Before starting the operation, the tool is at (5, 4). The G and N codes for this motion ... 0 I5.0 J2.0 c.N010 GO1 X7.0 Y2.0 I5.0 J2.0 d.N010 GOO X7.0 Y2.0 I5.0 J2.0

Last Answer : b.N010 GO2 X7.0 Y2.0 I5.0 J2.0

Description : Which one of the following statements is true? a. Business-as-usual activities cannot be improved. b. Business-as-usual activities are more difficult to manage than projects. c. Projects are ... change to business-as-usual. d. A project is always the starting point for operation refinement

Last Answer : c. Projects are transient endeavours that bring about change to business-as-usual.

Description : Which one of the following statements is true?  a. Business-as-usual activities cannot be improved.  b. Business-as-usual activities are more difficult to manage than projects.  c. Projects are ... change to business-as-usual.  d. A project is always the starting point for operation refinement.

Last Answer : c. Projects are transient endeavours that bring about change to business-as-usual

Description : Often earing defects are found during deep drawing operation, because the (A) Surface finish of the sheet is poor (B) Sheet material has been given substantial spring back (C) Starting sheet has planer anisotropy due to its texture (D) Starting sheet has normal anisotropy due to its texture

Last Answer : (C) Starting sheet has planer anisotropy due to its texture

Description : Which of the following is least acceptable Learning may Options: A) Be acquired without intent B) Occur independently of past-experience C) Be detrimental to the individual D) Take place without operation of movies and goals

Last Answer : D) Take place without operation of movies and goals 

Description : Give the operation of single phase full wave bridge controlled converter with RL load with a neat diagram. Also draw its waveform.

Last Answer : Single phase fully control bridge converter with RL load: 1. During positive half cycle of input voltage, T1 and T2 are forward biased and during negative half cycle, T3 and T4 are forward biased. Therefore, T1-T2 ... cycle till the firing of next pair of SCRs as shown in the waveform.

Description : A generator has been exposed to water and is being checked for its safe operation. Therefore, it is necessary to _______________. A. check for shorted coils with a growler B. take moisture readings with a ... a megger D. ground the commutator, or slip rings and run it at half load for 12 hours

Last Answer : Answer: C

Description : Column 1,2 and 3 contain starting materials, reaction conditions, and type of reactions, respectively The only CORRECT combination that gives two diff

Last Answer : Column 1,2 and 3 contain starting materials, reaction conditions, and type of reactions, respectively The only CORRECT ... )(i)(S) D. (III)(iii)(P)

Description : Column 1,2 and 3 contain starting materials, reaction conditions, and type of reactions, respectively For the synthesis of benzoic acid, the only CORR

Last Answer : Column 1,2 and 3 contain starting materials, reaction conditions, and type of reactions, respectively For the synthesis ... )(ii)(P) D. (III)(iv)(R)

Description : Under normal conditions, storage batteries used for starting the emergency diesel generator are maintained in a charged state by which of the following methods? A. Trickle charging B. Fast charging C. Equalizing charge D. Reverse charging

Last Answer : Answer: A

Description : In the time-cost optimisation, using CPM method for network analysis, the crashing of the activities along the critical path is done starting with the activity having (A) Longest duration (B) Highest cost slope (C) Least cost slope (D) Shortest duration

Last Answer : (C) Least cost slope