The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : The single phasing relays are used for the protection of three phase motors.

Show More

296 views 1 answer







IDMT relays are used to protect the transformer against :  (A) Internal short -circuits (B) Open circuits (C) External short circuits (D) Oil leakage
Last Answer : IDMT relays are used to protect the transformer against : External short circuits

Show More

3.1k views 1 answer








Last Answer : Discrimination between main and back up protection is provided by the use of relays which are slow.

Show More

396 views 1 answer








Last Answer : The relay with inverse time characteristic will operate within 5 to 10 sec.

Show More

115 views 1 answer








Last Answer : Over voltage protection is recommended for hydro-electric generators, steam turbine generators, gas turbine generators.

Show More

98 views 1 answer







To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ?
Last Answer : To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ? Δ-Δ connection

Show More

558 views 1 answer








Last Answer : Impedance relays are used for phase faults on long line.

Show More

82 views 1 answer







If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be
Last Answer : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be 10

Show More

289 views 1 answer







If the % reactance upto the fault point is 20%, then the short circuit current will be
Last Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current

Show More

3.0k views 1 answer







In which fault the maximum short circuit current occurs?
Last Answer : In three phase bolted fault the maximum short circuit occurs.

Show More

130 views 1 answer







The inverse definite mean time relays are used for over current and earth fault protection of transformer against (a) heavy loads (b) internal short-circuits (c) external short-circuits (d) all of the above
Last Answer : (b) internal short-circuits

Show More

13 views 1 answer







With fault clearing time, the transient stability of a power system
Last Answer : With fault clearing time, the transient stability of a power system decreases

Show More

152 views 1 answer







A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay
Last Answer : D

Show More

547 views 2 answers







Surge absorbers are used for protection against
Last Answer : Surge absorbers are used for protection against low voltage high frequency oscillations

Show More

3.0k views 1 answer







In the induction type directional over current relay, when a short-circuit occurs in the circuit (A) power flows in reverse direction (B) power flows in normal direction (C) directional power element does not operate (D) over current element is not energized
Last Answer : In the induction type directional over current relay, when a short-circuit occurs in the circuit power flows in reverse direction

Show More

122 views 1 answer







If the fault current is 2000 A, the relay setting is 50% and CT ratio is 400:5, the plug setting multiplier will be
Last Answer : If the fault current is 2000 A, the relay setting is 50% and CT ratio is 400:5, the plug setting multiplier will be 10 A

Show More

379 views 1 answer







A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines
Last Answer : A negative sequence relay is used for protection of Generator 

Show More

627 views 1 answer







Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker
Last Answer : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Show More

260 views 1 answer








Last Answer : Thermal overload relays are used to protect the motor against overcurrent due to heavy loads.

Show More

252 views 1 answer







Select insulating materials for following parts : (i) Insulation between heating element and base plate of electric iron. (ii) Insulation used over copper or aluminium conductor used for making coils. (iii) Transformer bushings. (iv) Insulation between transmission line and pole.
Last Answer : Parts Insulating Materials  Insulation between heating element and base plate of electric iron. Mica Insulation used over copper or aluminium conductor used for making coils.  ... Transformer bushings Porcelain  Insulation between transmission line and pole. Porcelain

Show More

199 views 1 answer







If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then  (A) zero sequence currents are present on both sides of the transformer  (B) ... side  (D) zero sequence currents are present on the primary side but not on the secondary side
Last Answer : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then zero sequence currents are absent on both sides of the transformer 

Show More

227 views 1 answer








Last Answer : To protect most of the electrical equipment handling low power, the types of relays used are thermocouple, electronic and bimetallic.

Show More

106 views 1 answer








Last Answer : Protective relays are devices that detect abnormal conditions in electrical circuits by measuring constantly the electrical quantities which differ during normal and abnormal conditions.

Show More

132 views 1 answer








Last Answer : Directional relays are based on flow of power.

Show More

165 views 1 answer







D.C. shunt relays are made of?
Last Answer : D.C. shunt relays are made of many turns of thin wire.

Show More

2.7k views 1 answer








Last Answer : Overload relays are of induction, solid state, thermal, electromagnetic type.

Show More

72 views 1 answer








Last Answer : Relays can be designed to respond to changes in resistance, reactance or impedance voltage and current, light intensity, temperature.

Show More

145 views 1 answer







The operating point of a protective current transformer is near the
Last Answer : The operating point of a protective current transformer is near the Ankle point

Show More

126 views 1 answer







The inrush current of a transformer at no load is maximum if the supply voltage is switched on  (1) at peak voltage value (2) at zero voltage value (3) at half voltage value (4) at 0.866 time voltage value
Last Answer : At 0.866 time voltage value

Show More

114 views 2 answers







3 phase 11KV to 4 10000 KVA alternator has neutral Earth through a resistance of 1 ohm the machine has current balance protection while operate upon of balance Karan exceed 18% of full load determine percentage of winding and protected against ground fault

Show More

25 views 0 answers








Last Answer : Reactance relay is preferred for phase fault on short transmission line.

Show More

110 views 1 answer








Last Answer : Fault diverters are basically fast switches.

Show More

561 views 1 answer







Which is the most common type of fault?
Last Answer : Single phase to ground fault is the most common type of fault.

Show More

135 views 1 answer







ln HRC fuse the time between cut-off and final current zero is called
Last Answer : ln HRC fuse the time between cut-off and final current zero is called the arcing time

Show More

139 views 1 answer







3X3 inverse of matrix short trick
Last Answer : 3X3 inverse of matrix short trick

Show More

292 views 1 answer







For a given matrix inverse of a matrix is

Show More

85 views 0 answers







What is the inverse of reactance?
Last Answer : Inverse of reactance is Susceptance .Unit of Susceptance is Siemens.

Show More

141 views 1 answer







For protection of rotating machines against lightning surges _______ is used.  (1) lightning arrester (2) capacitor (3) combination of lightning arrester and capacitor (4) lightning conductor and arrester
Last Answer : For protection of rotating machines against lightning surges combination of lightning arrester and capacitor is used. 

Show More

4.5k views 1 answer







Reactance relay is normally preferred for protection against
Last Answer : Reactance relay is normally preferred for protection against earth faults

Show More

120 views 1 answer








Last Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

Show More

157 views 1 answer








Last Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Show More

94 views 1 answer








Last Answer : A thermal protection switch can protect against overload.

Show More

233 views 1 answer







How many types of types of relays are there?

Show More

50 views 0 answers







Consider the following statements. Which of these statements are correct ?  (1) Reactance relays are preferred for ground fault relaying  (2) Impedance relays are most suitable for:protecting long transmission lines  (3) Mho relays are best ... (1) and (3) (C) (2) and (4) (D) (1), (2) and (4)
Last Answer : Consider the following statements. Which of these statements are correct ?  (1) Reactance relays are preferred for ground fault relaying  (2) Impedance relays are most suitable for:protecting long transmission lines  (3) Mho relays are ... (1) and (3) (C) (2) and (4) (D) (1), (2) and (4)

Show More

129 views 1 answer







Eddy current damping cannot be used for moving iron instrument because
Last Answer : Eddy current damping cannot be used for moving iron instrument because the presence of a permanent magnet required for such purpose would affect the deflection and hence the reading of the instrument

Show More

2.3k views 1 answer







How can a magnetic field be used to generate an electric current?
Last Answer : Magnetic  field  can  be  used  to  generate  electric  current  on  a  condition  that  it  is  on  a  rate  of  changing  magnetic  flux.  (Faraday's  law)

Show More

106 views 1 answer







What type of meter is used to measure current?
Last Answer : Ammeter

Show More

2.7k views 3 answers













Step-down transformer converts high voltage and low current into:  (A) How voltage and high current (B) High voltage and low current (C) Low voltage and high current (D) None of the above
Last Answer : Step-down transformer converts high voltage and low current into: Low voltage and high current

Show More

123 views 1 answer







In a single-phase transformer, the magnetizing current is (A) in phase with the no-load current (B) in quadrature with the no-load current (C) the product of no-load current and power factor (D) in phase with the flux in the core
Last Answer : In a single-phase transformer, the magnetizing current is in phase with the flux in the core

Show More

86 views 1 answer